The Honeywell TrueDRY DR90 is a high-capacity dehumidifier designed for residential and light commercial use. It features a 90-pint per day removal capacity (at AHAM conditions), digital humidistat control with auto-defrost, continuous drain option, washable air filter, full tank alert with auto-shutoff, casters for mobility, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital control panel, 90-pint water tank with handle and indicator, washable air filter, continuous drain hose connection, casters, and auto-defrost function.
| Feature | Description |
|---|---|
| Removal Capacity | 90 pints per day (at 80°F, 60% RH) |
| Digital Humidistat | Set desired humidity level (35% - 85%) |
| Auto-Defrost | Prevents coil freezing in low temperatures |
| Continuous Drain | Option for hose connection (hose not included) |
| Full Tank Alert | Indicator light and auto-shutoff when tank is full |
| Washable Air Filter | Captures dust and particles; reusable |
| Casters | Four wheels for easy room-to-room mobility |
| Energy Efficient | ENERGY STAR® qualified model |
| Control Lock | Prevents accidental setting changes |
| 24-Hour Timer | Program on/off cycles |
Unpack and inspect contents. Place on a level, stable floor surface.
WARNING! Do not place in temperatures below 41°F (5°C) or above 95°F (35°C). Ensure the unit is upright for at least 24 hours before first use if transported on its side.
Power on the dehumidifier; follow control panel prompts.
CAUTION! Handle the water tank with care; empty before moving the unit.
Access all functions via the digital control panel on top of the unit.
Control Panel: POWER button, HUMIDITY +/- buttons, FAN SPEED (HIGH/LOW), TIMER, FILTER RESET indicator, FULL TANK indicator, CONTROL LOCK.
Operation Modes: Normal (set humidity), Continuous (runs until tank is full or turned off). Settings: Humidity level (35%-85%), Fan speed (High/Low), Timer (1-24 hours), Auto-restart (resumes previous settings after power outage). Indicators: Power On, Full Tank, Filter Clean, Defrost (flashes during auto-defrost cycle).
Two methods: Manual (water tank) or Continuous (drain hose).
Tip: For continuous drainage, place unit on a stable surface higher than the drain point. Ensure hose is free of kinks.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug the unit before any maintenance. Do not immerse in water.
Set humidity to 50% or higher when away. Use in enclosed spaces with doors/windows closed. Ensure filter is clean for efficient airflow. Use continuous drain in high-humidity areas to avoid frequent tank emptying.
This product complies with FCC Part 15 Subpart B. It may not cause harmful interference and must accept any interference received. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147. ENERGY STAR® is a registered trademark of the U.S. Environmental Protection Agency.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | Power issue / Full tank | Ensure plugged in; outlet has power; empty water tank and reinsert properly. |
| Reduced moisture removal | Dirty filter / Low temp | Clean air filter; ensure room temp is above 41°F (5°C). |
| Water leaking | Tank not seated / Hose leak | Ensure tank is pushed in fully; check hose connections for continuous drain. |
| Loud or unusual noise | Loose parts / Fan obstruction | Ensure unit is on level surface; check for objects near fan intake/exhaust. |
| Frost on coils | Low temperature operation | Auto-defrost should activate; move to warmer area if below 41°F. |
| Control panel unresponsive | Control lock enabled | Press and hold CONTROL LOCK button for 3 seconds to disable. |
Reset: Unplug for 60 seconds, then plug back in to reset electronic controls.
Service: 1-800-474-2147; www.honeywellhome.com. Do not attempt to repair refrigerant system.