Honeywell TRUEDRY DH150 Dehumidifier Manual

The Honeywell TRUEDRY DH150 is a high-capacity dehumidifier designed for residential and light commercial use, capable of removing up to 150 pints of moisture per day. It features digital humidity control, an auto-restart function, a continuous drain option, a washable filter, and a 24-hour timer. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Instructions 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, Water tank with full indicator, Washable air filter, Casters for mobility, Continuous drain hose connection, Auto-defrost function.

FeatureDescription
Moisture RemovalUp to 150 pints per day (at 80°F, 60% RH)
Digital Control PanelSet and monitor target humidity level
Auto-RestartResumes previous settings after power interruption
Continuous Drain OptionConnect hose for unattended operation
Washable FilterCaptures airborne particles; reusable
24-Hour TimerProgram on/off cycles
Full Tank AlertIndicator light and auto shut-off when tank is full
CastersEasy mobility between rooms
Auto-DefrostPrevents coil freezing in low temperatures
Energy EfficientENERGY STAR® certified

Installation

Unpack and inspect contents. Place on a level, stable floor.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Check Filter: Ensure washable filter is properly installed.
  3. Drain Setup: Choose between using the water tank or connecting the continuous drain hose (included).
  4. Power Connection: Plug directly into a grounded 120V AC outlet. Do not use an extension cord.

WARNING! Ensure the unit is upright for at least 2 hours before first use if it was tilted during transport.

First-Time Setup

Plug in the dehumidifier; the control panel will illuminate.

  1. Set Target Humidity: Press the HUMIDITY button to set desired level (35% - 85%).
  2. Select Fan Speed: Choose LOW or HIGH fan speed using the FAN button.
  3. Set Timer (Optional): Use TIMER button to program automatic start/stop times.
  4. Start Operation: Press the POWER button to begin dehumidifying.

CAUTION! Do not place in an area where water leakage could cause damage. Ensure the drain hose is securely connected if used.

Specifications

Controls and Settings

Access all functions via the digital control panel on top of the unit.

Control Panel: POWER button, HUMIDITY +/- buttons, FAN SPEED button, TIMER button, FILTER ALERT indicator, FULL TANK indicator.

Humidity Control: Set target from 35% to 85% in 5% increments. Fan Speed: LOW for quiet operation, HIGH for maximum moisture removal. Timer: Program on/off cycles in 1-hour increments up to 24 hours. Indicators: FILTER light alerts when filter needs cleaning; FULL TANK light and auto shut-off activate when water tank is full.

Operating Instructions

For Tank Operation: Unit will run until tank is full, then shut off. Empty tank and restart. For Continuous Drain: Connect hose to drain port and lead to floor drain or sump pump; unit can run unattended.

  1. Power On: Press POWER button.
  2. Set Humidity: Use HUMIDITY buttons to set desired level.
  3. Monitor: Current room humidity is displayed. Unit cycles on/off to maintain set point.
  4. Empty Tank: When FULL light comes on, power off, remove tank, empty, replace, and restart.
  5. Use Timer: Set TIMER for automatic operation (e.g., run only at night).

Tip: For best efficiency, keep doors and windows closed in the room being dehumidified.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Clean Air Filter: Remove filter every 2 weeks (or when FILTER light is on). Wash with warm, soapy water, rinse, and air dry completely before reinstalling.
  2. Clean Exterior: Wipe cabinet with a soft, damp cloth. Do not use harsh chemicals.
  3. Clean Water Tank: Empty and clean tank monthly with mild detergent to prevent mold/mildew.
  4. End-of-Season: Follow storage instructions if not using for extended period.

WARNING! Never immerse the unit in water. Do not operate without the air filter installed.

Storage Instructions

If storing the dehumidifier for more than a few weeks:

  1. Unplug the unit and empty the water tank completely.
  2. Clean the tank and air filter as described above. Ensure all parts are completely dry.
  3. Coil the power cord neatly.
  4. Store in a cool, dry place, preferably in the original carton.

CAUTION! Store upright. Do not place heavy objects on top of the unit.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. TRUEDRY is a trademark of Honeywell. For support, visit www.honeywellhome.com or contact customer service at 1-800-474-2147.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Full tankEnsure plug is secure; Check if FULL light is on and empty tank; Wait 3 minutes after unplugging to restart.
Little or no water collectionLow humidity / Cold room / Dirty filterRoom may already be dry; Unit runs less. Ensure room temp is above 41°F. Clean the air filter.
Unit runs constantlyHigh humidity setting / LeaksSet humidity to a higher % (e.g., 50%). Check for open doors/windows or water leaks in room.
Loud or unusual noiseUneven surface / Loose partsPlace unit on a level floor. Ensure water tank and filter are correctly seated.
Error Code "E1" displayedSensor faultUnplug for 5 minutes, then restart. If persists, contact service.
Frost on coilsLow temperature operationAuto-defrost should activate. If frost persists, turn unit off and let ice melt. Use only above 41°F.

Reset: Unplug unit for 5 minutes to reset control system.

Service: 1-800-474-2147; www.honeywellhome.com