Honeywell TPFIT50WK Dehumidifier Manual

The Honeywell TPFIT50WK is a 50-pint portable dehumidifier designed for medium to large rooms, featuring an adjustable humidistat, continuous drain option, auto-restart, full tank alert with auto-shutoff, washable filter, caster wheels for mobility, and quiet operation. Ideal for basements, living areas, and other damp spaces up to 3000 sq ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Portable unit with built-in handle, water tank, humidistat control panel, air filter, continuous drain hose port, and caster wheels.

FeatureDescription
HumidistatAdjustable humidity level control (30% - 80%)
Water TankRemovable 1.8-gallon bucket with full indicator
Continuous DrainHose connection for unattended operation
Auto Shut-OffStops operation when tank is full
Washable FilterCaptures dust and airborne particles
Caster WheelsFour wheels for easy room-to-room mobility
Auto-RestartResumes previous settings after power interruption
Quiet OperationLow noise design for living spaces
Timer FunctionProgrammable 1-24 hour on/off timer
Turbo ModeHigh-speed dehumidification for rapid moisture removal

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 6 inches from walls and furniture for proper airflow.
  2. Room Size: Suitable for areas up to 3000 sq ft with moderate humidity.
  3. Temperature Range: Operate between 41°F (5°C) and 95°F (35°C).
  4. Drain Options: Use bucket or connect hose for continuous drainage.

WARNING! Do not place in tight enclosures or block air vents. Ensure unit is upright during operation.

First-Time Setup

Remove all packaging materials and prepare for operation.

  1. Install filter: Ensure washable filter is properly seated in front grille.
  2. Check tank: Verify water bucket is correctly inserted and empty.
  3. Power connection: Plug into dedicated 120V AC outlet.
  4. Initial settings: Set desired humidity level using control panel.
  5. Test operation: Power on and verify fan and compressor engage.

CAUTION! Do not operate with damaged cord or plug. Keep cord away from heated surfaces.

Specifications

Controls and Settings

Control Panel: POWER, MODE, FAN SPEED, HUMIDISTAT, TIMER, TURBO.

Display Indicators: Power, Full Tank, Filter Clean, Target Humidity, Timer.

Humidity Control: Adjust between 30%-80% RH. Fan Speed: Low/High settings. Mode Selection: Continuous or Auto (humidity-based). Timer: Set 1-24 hours for automatic start/stop. Turbo Mode: Maximum moisture removal. Filter Alert: LED indicates when filter needs cleaning.

Operation Modes

Auto Mode: Maintains set humidity level automatically. Continuous Mode: Runs continuously regardless of humidity. Turbo Mode: High-speed dehumidification.

  1. Select desired humidity level using +/- buttons.
  2. Choose fan speed (Low for quiet, High for faster drying).
  3. Enable Turbo for maximum performance in very damp conditions.
  4. Use Timer to schedule operation periods.

Tip: For energy efficiency, set humidity to 45-50% for most living spaces.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Empty tank: Regularly check and empty water bucket.
  2. Clean filter: Remove and wash filter every 2-4 weeks with warm water.
  3. Exterior cleaning: Wipe cabinet with soft, damp cloth.
  4. Coil inspection: Keep evaporator coils free of dust and debris.
  5. Drain hose: Flush periodically if using continuous drainage.

WARNING! Always unplug unit before cleaning. Never immerse in water.

Storage & Winterization

Proper storage prevents damage during non-use periods.

  1. Clean unit thoroughly following maintenance instructions.
  2. Empty and dry water tank completely.
  3. Run in fan-only mode for 30 minutes to dry internal components.
  4. Store in upright position in dry, protected area.
  5. Cover unit to prevent dust accumulation.

CAUTION! Do not store with water in tank or lines to prevent mold and damage.

Safety Features

Auto Shut-Off: Stops operation when tank is full. Tip-Over Protection: Cuts power if unit tilts excessively. Overheat Protection: Thermal cutoff prevents compressor damage. Child Lock: Prevents accidental setting changes.

Regulatory Information

UL Listed: Meets UL 474 safety standards. Energy Star: Certified for energy efficiency. FCC Part 15: Complies with interference limits. California Prop 65 Warning: Contains chemicals known to cause cancer and reproductive harm. For support, visit www.honeywellhome.com or contact 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power outlet; ensure tank is empty and properly seated.
Poor dehumidificationRoom temp too low/filter dirtyOperate above 41°F; clean filter; check room size.
Water leakageTank not seated/hose connectionReinstall tank; check hose fittings for continuous drain.
Loud noiseUneven surface/foreign objectPlace on level floor; check for obstructions in fan area.
Ice on coilsLow temperature/high humidityRaise room temperature; defrost unit by turning off for 2 hours.
Filter light onDirty filterClean filter as per maintenance instructions.

Reset: Unplug for 5 minutes, then restart. Check circuit breaker if no power.

Service: 1-800-332-1110; www.honeywellhome.com