Honeywell TPFIT50PWK Dehumidifier Manual

The Honeywell TPFIT50PWK is a 50-pint portable dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drainage option, washable air filter, auto restart, turbo mode for faster moisture removal, and a digital display with humidity readout. It operates on 115V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, washable air filter, water tank with full indicator, continuous drainage port, casters for mobility, and adjustable humidity settings.

FeatureDescription
Digital DisplayShows current humidity level, settings, and alerts
Adjustable HumidistatSet desired humidity level from 35% to 85%
Auto DefrostPrevents coil freezing in low temperatures
Continuous DrainageOption to connect hose for automatic water removal
Washable Air FilterCaptures dust and particles; reusable
Turbo ModeIncreases fan speed for maximum moisture removal
Auto RestartResumes previous settings after power interruption
Full Tank AlertAlarm and auto shut-off when tank is full
24-Hour TimerProgram on/off cycles
Portable DesignBuilt-in handles and casters for easy movement

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 6 inches from walls and furniture for proper airflow.
  2. Environment: Operate in enclosed spaces between 41°F and 95°F for optimal performance.
  3. Drainage Setup: For continuous drainage, attach hose to drain port and route to floor drain or sink.
  4. Power Connection: Plug directly into grounded 115V outlet; avoid extension cords.

WARNING! Do not place in areas with standing water. Ensure unit is upright before operation.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Insert filter: Ensure washable air filter is properly seated.
  2. Set humidity: Press HUMIDITY button to select desired level (recommended 45-50%).
  3. Select mode: Choose between Normal, Turbo, or Continuous operation.
  4. Check drainage: Ensure water tank is empty and securely in place.

CAUTION! Handle with care; unit contains refrigerant. Do not tilt or invert.

Specifications

Controls and Settings

Access controls via digital panel. Buttons: POWER, MODE, HUMIDITY, TIMER, TURBO, FILTER RESET.

Display Icons: Power, Tank Full, Filter Clean, Defrost, Turbo, Timer, Humidity Level.

Humidity Control: Set target humidity (35%-85%). Modes: Normal (standard operation), Turbo (high speed), Continuous (runs until tank is full). Timer: Program 1-24 hours for automatic start/stop. Filter Alert: Illuminates when filter needs cleaning. Auto Defrost: Activates automatically in low temperatures.

Operation Modes

Normal Mode: Standard dehumidification at set humidity level. Turbo Mode: Maximum moisture removal for damp conditions. Continuous Mode: Runs until tank is full (ignores humidity setting).

  1. Press POWER to turn on.
  2. Press MODE to cycle through Normal, Turbo, Continuous.
  3. Press HUMIDITY to adjust target level.
  4. Press TIMER to set automatic shut-off or start delay.
  5. Monitor display for current humidity and alerts.

Tip: Use Turbo mode initially in very damp spaces, then switch to Normal.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Empty Water Tank: When full indicator lights, turn off, remove tank, empty, and replace.
  2. Clean Air Filter: Remove monthly, wash with warm water and mild detergent, dry completely before reinstalling.
  3. Exterior Cleaning: Wipe cabinet with soft, damp cloth; do not use chemicals.
  4. Coil Inspection: Check evaporator coil annually for dust; clean gently with soft brush.
  5. Drainage Hose: If used, flush periodically to prevent clogs.

WARNING! Unplug before cleaning. Do not immerse unit in water.

Storage & Winterization

If not using for extended period (e.g., winter), prepare for storage.

  1. Unplug unit and empty water tank completely.
  2. Clean filter and let all parts dry thoroughly.
  3. Coil storage: Run in fan-only mode for 30 minutes to dry internal components.
  4. Store upright in cool, dry place; cover to prevent dust.

CAUTION! Do not store with water in tank or lines to prevent mold.

Regulatory Information

UL Listed; meets U.S. safety standards. EPA compliant. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110. This product contains refrigerant; follow local disposal regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower supplyEnsure plugged in; check outlet; press POWER firmly.
Low moisture removalRoom conditions/filterEnsure room temp 41-95°F; clean filter; close windows/doors.
Water tank not fillingHumidity level/placementCheck set humidity; ensure unit is level; room may already be dry.
Loud noise/vibrationPlacement/obstructionPlace on level floor; ensure nothing touching unit; check for loose parts.
Error code on displaySystem faultRefer to manual code list; unplug for 10 minutes, then restart.
Filter light onDirty filterClean filter as instructed; press FILTER RESET.
Ice on coilsLow temperatureAuto defrost should activate; move to warmer area if below 41°F.

Reset: Unplug for 10 minutes to reset control board.

Service: 1-800-332-1110; www.honeywellhome.com