The Honeywell TPFIT32AWK is a 32-pint portable dehumidifier designed for medium-sized rooms up to 1500 sq ft. It features automatic humidity control, a continuous drain option, a washable filter, a full-bucket alert with auto-shutoff, and a 24-hour timer. This manual covers safety instructions, features, installation, operation, maintenance, and troubleshooting for optimal performance.
Key components: Portable unit with built-in handle, Control Panel, Water Bucket, Continuous Drain Hose Outlet, Washable Air Filter, and Humidity Sensor.
| Feature | Description |
|---|---|
| Capacity | Removes up to 32 pints per day (at 80°F, 60% RH) |
| Humidity Control | Auto mode with adjustable set point (35% - 85% RH) |
| Continuous Drain | Optional hose connection for unattended operation |
| Full Bucket Alert | Indicator light and auto-shutoff when bucket is full |
| Timer | 24-hour programmable on/off timer |
| Filter | Washable air filter for improved air quality |
| Portability | Built-in handles and caster wheels for easy movement |
| Display | Digital control panel with humidity readout |
| Power Cord | Standard 115V, 60Hz plug |
| Operating Range | 41°F to 95°F |
Unpack and inspect contents. Place on a level, stable surface.
WARNING! Do not use in temperatures below 41°F. Ensure the unit is upright before operating.
Power on the dehumidifier; the control panel will illuminate.
CAUTION! Do not block air vents. Keep the unit away from curtains and other obstructions.
Access all functions via the digital control panel on top of the unit.
Control Panel: POWER, MODE (Auto/Continuous), HUMIDITY SET (+/-), FAN SPEED (High/Low), TIMER, FILTER RESET indicator, FULL BUCKET indicator.
Humidity Control: Set desired level from 35% to 85% RH. The unit will cycle on/off to maintain this level in AUTO mode. Fan Speed: HIGH for maximum moisture removal, LOW for quieter operation. Timer: Program to turn on/off up to 24 hours in advance. Alerts: FILTER light indicates when to clean the filter; BUCKET light signals when to empty the water container.
Auto Mode: Unit monitors room humidity and runs only when needed to maintain set point. Continuous Mode: Runs constantly until manually turned off or bucket is full. Laundry Mode: Optional high-speed setting for drying laundry in enclosed spaces (refer to advanced settings).
Tip: Close windows and doors in the room for most efficient operation.
Regular maintenance ensures efficiency and longevity.
WARNING! Always unplug before cleaning. Never immerse unit in water.
If not using for extended period (e.g., winter):
CAUTION! Do not store with water in bucket or lines to prevent damage and mold.
This dehumidifier complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. This product is Energy Star certified, meeting strict energy efficiency guidelines set by the U.S. EPA. For support, visit www.honeywellhome.com or contact customer service at 1-800-474-2147. Copyright © Honeywell International Inc.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | No power / Full bucket | Ensure plug is secure; empty bucket and reinstall properly. |
| Not removing moisture | Room temp too low / Dirty filter | Use only above 41°F; clean air filter; check that doors/windows are closed. |
| Water leaking | Bucket not seated / Hose connection | Remove and reinsert bucket; check hose for kinks/leaks. |
| Loud or unusual noise | Uneven surface / Loose parts | Place on level floor; ensure bucket and panels are secure. |
| Frost on coils | Low temperature / Dirty filter | Turn off and allow to thaw; clean filter; increase room temp if possible. |
| FILTER light on | Dirty air filter | Clean filter as instructed; press FILTER RESET button. |
Reset: Unplug for 60 seconds, then plug back in to reset control board.
Service: 1-800-474-2147; www.honeywellhome.com