Honeywell TPFIT25WK Dehumidifier Manual

The Honeywell TPFIT25WK is a 25-pint portable dehumidifier designed for medium-sized rooms up to 1500 sq ft. It features a built-in humidistat with adjustable settings, continuous drain option, auto-defrost for low-temperature operation, washable air filter, full tank alert with auto-shutoff, and quiet operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Portable unit with carrying handle, Control Panel, Water Tank, Air Filter, Drain Hose Connector, Power Cord.

FeatureDescription
HumidistatAdjustable humidity control from 35% to 85% RH
Water TankRemovable 1.8-gallon capacity with full tank indicator
Continuous DrainGarden hose connection for continuous operation
Auto-DefrostAutomatically defrosts coils in low temperatures
Washable FilterReusable air filter for improved air quality
Auto-RestartResumes previous settings after power interruption
Turbo ModeHigh-speed dehumidification for maximum moisture removal
Quiet OperationLow noise level for bedroom or office use
Full Tank AlertLED indicator and auto-shutoff when tank is full
Carrying HandleIntegrated handle for easy portability

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room or area with high humidity, away from walls/furniture (minimum 12 inches clearance).
  2. Check ventilation: Ensure air intake and exhaust are unobstructed.
  3. Connect drain hose (optional): Attach standard garden hose to drain outlet for continuous drainage.
  4. Plug into grounded 120V AC outlet.

WARNING! Do not place near heat sources or in direct sunlight. Ensure proper electrical grounding.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Install filter: Remove filter from packaging and insert into filter compartment.
  2. Set humidity level: Press HUMIDITY button to set desired RH percentage (recommended 45-50%).
  3. Select mode: Choose between Normal, Turbo, or Continuous mode based on needs.
  4. Test operation: Allow unit to run for 15 minutes to ensure proper condensation collection.

CAUTION! Handle water tank carefully when removing. Do not operate without filter installed.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, TIMER, TURBO, FILTER RESET.

Display Indicators: Current Humidity, Set Humidity, Full Tank, Filter Alert, Turbo Mode, Timer.

Humidity Settings: Press HUMIDITY to adjust target RH level (35%-85%). Mode Selection: Normal (standard operation), Continuous (runs until tank full or turned off). Timer: Set 1-24 hour ON/OFF timer. Turbo Mode: Maximum moisture removal. Filter Reset: Reset filter maintenance indicator after cleaning.

Operation Modes

Normal Mode: Standard dehumidification with humidistat control. Continuous Mode: Runs continuously regardless of humidity level. Turbo Mode: High fan speed for rapid dehumidification.

  1. Press POWER to turn unit on.
  2. Select MODE to choose between Normal, Continuous, or Turbo.
  3. Adjust HUMIDITY setting to desired level.
  4. Monitor water collection in tank or through drain hose.

Tip: For energy efficiency, set humidity to 45-50% and use Normal mode.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean filter: Remove and wash filter every 2 weeks with warm water, dry completely before reinstalling.
  2. Empty water tank: Regularly empty tank before it reaches full capacity.
  3. Clean exterior: Wipe with soft, damp cloth; do not use harsh chemicals.
  4. Clean coils: Use soft brush to remove dust from coils every 3 months.
  5. Off-season storage: Empty tank completely, clean unit, and store in dry place.

WARNING! Always unplug unit before cleaning. Never immerse in water.

Drainage Options

Two drainage methods: Manual (water tank) or Continuous (drain hose).

Manual Drainage: Unit stops when tank is full (indicator lights). Remove tank, empty, and replace.

Continuous Drainage: Connect standard garden hose (not included) to drain outlet. Ensure hose runs downward to floor drain or sink.

Regulatory Information

UL Listed: Meets safety standards for household use. Energy Star: May qualify for Energy Star certification (check model specifics). FCC Part 15: Class B digital device compliance. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueCheck power cord connection; ensure outlet is working; check circuit breaker.
Not collecting waterTemperature/humidityEnsure room temperature above 41°F; check humidity level; clean air filter.
Water leakingTank/drain hoseEnsure tank properly seated; check drain hose connection; empty full tank.
Loud noisePlacement/fanEnsure unit on level surface; check for obstructions in fan area.
Filter light onDirty filterClean air filter; press and hold FILTER RESET for 3 seconds.
Ice on coilsLow temperatureAuto-defrost should activate; move to warmer area if below 41°F.

Reset: Unplug for 5 minutes, then restart.

Service: 1-800-332-1110; www.honeywellhome.com

Honeywell TPFIT25WK Dehumidifier Manual © - All Rights Reserved 2025