The Honeywell TP70WK is a 70-pint dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drain option, washable filter, digital display with humidity readout, auto-restart after power interruption, 24-hour timer, full tank alert with auto-shutoff, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, Water tank with handle, Washable air filter, Continuous drain hose connection, Casters for mobility, Humidity sensor.

FeatureDescription
Digital Control PanelLED display with humidity readout and touch controls
70-Pint CapacityRemoves up to 70 pints per day at 65°F/60% RH
Automatic Humidity ControlSet desired humidity level (35%-85%)
Continuous Drain OptionGarden hose connection for unattended operation
Washable Air FilterRemovable filter for easy cleaning
Auto RestartResumes previous settings after power outage
24-Hour TimerProgram on/off cycles
Full Tank AlertLED indicator and auto-shutoff when tank is full
Casters & HandlesEasy mobility between rooms
Energy EfficientEnergy Star certified operation

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Remove all packaging materials and tape.
  2. Place unit on level floor with at least 12-18 inches clearance on all sides.
  3. Ensure proper room size: Up to 4,500 sq. ft. in moderate humidity conditions.
  4. Keep away from heat sources, direct sunlight, and obstructions to airflow.
  5. Install casters if not pre-attached.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure proper ventilation around unit.

First-Time Setup

Plug into grounded outlet; follow initial setup procedure.

  1. Check filter: Ensure washable filter is properly installed.
  2. Insert water tank: Slide tank completely into base until it clicks.
  3. Power on: Plug into 120V outlet, press POWER button.
  4. Set humidity: Use UP/DOWN buttons to set desired humidity (45-50% recommended).
  5. Select mode: Choose between Continuous, Auto, or Timer mode.
  6. For continuous drain: Connect garden hose to drain port before operation.

CAUTION! Use only grounded outlet. Do not use extension cord.

Specifications

Controls and Settings

Digital Control Panel: POWER, MODE, TIMER, UP/DOWN buttons, FILTER indicator, FULL TANK indicator.

Display Indicators: Current humidity, Set humidity, Timer setting, Filter alert, Full tank alert, Mode indicator.

Humidity Control: Adjust between 35%-85% RH in 5% increments. Modes: Continuous (runs constantly), Auto (maintains set humidity), Timer (programmable on/off). Fan Speed: High/Low settings adjustable via MODE button. Filter Reset: Hold FILTER button for 3 seconds after cleaning. Timer: Program 1-24 hours for automatic operation.

Operation Modes

Three operating modes for different needs.

  1. Auto Mode: Maintains set humidity level automatically. Unit cycles on/off as needed.
  2. Continuous Mode: Runs continuously regardless of humidity. Use for maximum moisture removal.
  3. Timer Mode: Set 1-24 hour operation. Unit turns off automatically after set time.
  4. Fan Only: Circulates air without dehumidifying (available in some settings).

Tip: For energy savings, use Auto mode with humidity set to 45-50%.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Daily: Check water tank, empty when full.
  2. Weekly: Check filter condition.
  3. Monthly: Clean air filter with warm water and mild detergent.
  4. Seasonally: Clean exterior with damp cloth; never use harsh chemicals.
  5. Annual: Check coils for dust; clean gently with soft brush.
  6. Storage: Empty tank, clean unit, store in dry place with cord wrapped.

WARNING! Unplug unit before any maintenance. Do not immerse in water.

Drainage Options

Two methods for water removal: Manual tank emptying or continuous drain.

  1. Manual Drain: Unit stops when tank is full (FULL indicator lights). Remove tank, carry to drain, empty, replace.
  2. Continuous Drain: Connect standard garden hose (not included) to drain port. Ensure hose runs downward to floor drain. Unit operates continuously without tank filling.
  3. Gravity Drain: Place unit higher than drain location for proper flow.

CAUTION! Ensure continuous drain hose is not kinked or blocked.

Safety Features

Built-in protections for safe operation.

FeatureFunction
Auto ShutoffStops operation when tank is full
Overheat ProtectionShuts off compressor if overheating detected
Auto DefrostPrevents frost buildup in low temperatures
Tip-Over ProtectionShuts off if unit is knocked over
Child LockPrevents accidental button presses
Filter AlertReminds when filter needs cleaning

Regulatory Information

ETL Listed: Meets safety standards. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device; complies with interference limits. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110. This product contains refrigerant R-410A. Proper disposal required by local regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is secure; check circuit breaker.
Not collecting waterLow humidityCheck room humidity; ensure temperature above 41°F.
Full tank light onTank full or not seatedEmpty tank; ensure tank is properly inserted.
Loud noiseUneven surface or obstructionPlace on level surface; check for objects near fan.
Filter light onDirty filterClean filter; press and hold FILTER button to reset.
Ice on coilsLow temperatureTurn off; allow ice to melt; increase room temperature.
Error code displayedSystem faultUnplug for 10 minutes; restart. If persists, contact service.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-332-1110; www.honeywellhome.com