The Honeywell TP70PWKNR is a 70-pint portable dehumidifier designed for residential use, featuring automatic humidity control, continuous drain option, washable filter, auto-restart, full tank alert with auto-shutoff, caster wheels for mobility, and digital controls with LED display. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Energy Saving Tips 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, 70-pint capacity tank, Washable air filter, Continuous drain hose connection, Caster wheels, Handle, Power cord, Full tank indicator.

FeatureDescription
Digital Control PanelLED display with humidity readout and control buttons
70-Pint CapacityRemoves up to 70 pints per day at 80°F/60% RH
Washable Air FilterCaptures airborne particles; reusable after cleaning
Continuous Drain OptionGarden hose connection for unattended operation
Caster Wheels & HandleFor easy portability between rooms
Auto Humidity ControlSet desired humidity level (35%-85%)
Full Tank AlertLED indicator and auto-shutoff when tank is full
Auto-RestartResumes previous settings after power interruption
24-Hour TimerProgram on/off cycles for energy savings
Turbo ModeMaximum moisture removal for high humidity conditions

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Remove packaging materials and tape from unit.
  2. Position dehumidifier: Ensure at least 12-18 inches clearance from walls and furniture for proper airflow.
  3. Install casters: Attach wheels to bottom of unit if not pre-installed.
  4. Check filter: Ensure washable filter is properly seated.
  5. Choose drainage: Decide between bucket collection or continuous drain hose.

WARNING! Do not operate in temperatures below 41°F (5°C). Keep away from heat sources and direct sunlight.

First-Time Setup

Plug into grounded 115V outlet; follow initial setup steps.

  1. Power on: Press POWER button; unit will beep and display current room humidity.
  2. Set humidity level: Press HUMIDITY button, then UP/DOWN arrows to set desired level (recommended 45-50%).
  3. Select mode: Choose between Normal, Turbo, or Continuous operation.
  4. Set timer (optional): Press TIMER button to program automatic on/off cycles.
  5. Check bucket: Ensure empty collection bucket is properly inserted.

CAUTION! Always use grounded outlet. Do not use extension cords.

Specifications

Controls and Settings

Control Panel: POWER, MODE, HUMIDITY, TIMER, FAN SPEED, FILTER RESET.

Display Indicators: Current humidity, Set humidity, Timer, Full tank, Filter clean, Turbo mode, Continuous mode.

Humidity Control: Set between 35%-85% RH in 5% increments. Modes: Normal (standard operation), Turbo (maximum dehumidification), Continuous (runs until tank full). Timer: Program 1-24 hours for automatic start/stop. Fan Speed: Adjust between Low and High. Filter Reset: Press after cleaning filter to reset indicator.

Operation Modes

Normal Mode: Standard operation at set humidity level. Turbo Mode: Maximum moisture removal for very damp conditions. Continuous Mode: Runs continuously regardless of humidity setting (until tank full).

  1. Select mode with MODE button.
  2. Adjust fan speed if desired (affects noise level and efficiency).
  3. Monitor display for current humidity and set point.
  4. Unit will cycle on/off automatically to maintain set humidity.

Tip: Close windows and doors in room being dehumidified for best results.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Empty water tank: When FULL indicator lights, remove and empty tank.
  2. Clean tank: Wash with mild detergent monthly; rinse thoroughly.
  3. Clean filter: Remove washable filter every 2 weeks; rinse with lukewarm water; air dry completely before reinstalling.
  4. Reset filter indicator: Press FILTER RESET after cleaning filter.
  5. Exterior cleaning: Wipe with damp cloth; never use harsh chemicals.
  6. End-of-season storage: Empty tank completely, clean unit, coil dry, store upright in dry location.

WARNING! Never operate without filter. Do not immerse unit in water.

Drainage Options

Bucket Collection: Standard method; empty when FULL indicator lights. Continuous Drain: Connect 5/8" ID garden hose to drain port.

  1. For continuous drain: Place unit near floor drain or sink.
  2. Remove drain cap from back of unit.
  3. Attach hose securely (not included).
  4. Ensure hose runs downward without kinks.
  5. Unit will drain continuously; bucket not needed in this mode.

CAUTION! Ensure proper hose connection to prevent leaks.

Energy Saving Tips

Set humidity to 50% or higher when possible. Use timer to run only during humid periods. Close windows and doors in dehumidified space. Ensure proper filter maintenance for efficient airflow. Use Normal mode instead of Turbo when humidity is moderately high. Position unit in center of problem area for optimal performance.

Regulatory Information

UL Listed. FCC Part 15: Class B digital device; complies with interference limits for residential use. This product contains chemicals known to cause cancer and birth defects or other reproductive harm (California Proposition 65). For support, visit www.honeywellhome.com or contact 1-800-332-1110. Manufactured for Honeywell International Inc.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/full tankCheck power connection; ensure tank is empty and properly inserted.
Low moisture removalFilter/door/ temperatureClean filter; ensure room sealed; check room temperature above 41°F.
Water leakingTank/hose connectionEnsure tank properly seated; check hose connection for continuous drain.
Loud noiseUneven surface/fanPlace on level surface; check for obstructions in fan area.
Display not workingPower/control issueUnplug for 5 minutes then restart; check power outlet.
Frost on coilsLow temperatureTurn off unit; allow to thaw; only use above 41°F.
Filter light onDirty filterClean filter as instructed; press FILTER RESET.

Reset: Unplug for 5 minutes to reset control system.

Service: 1-800-332-1110; www.honeywellhome.com