The Honeywell TP70PWK is a 70-pint capacity dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drain option, washable air filter, auto-restart after power interruption, full tank alert with auto-shutoff, turbo mode for faster dehumidification, and 24-hour timer. It operates on 115V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Control Panel, Water Tank, Air Filter, Drain Hose Connector, Casters for mobility, Handle for transport.
| Feature | Description |
|---|---|
| Humidity Control | Adjustable from 35% to 85% relative humidity |
| Water Tank | Removable 1.8-gallon capacity with full indicator |
| Continuous Drain | Hose connection for automatic draining |
| Air Filter | Washable mesh filter for dust and particles |
| Turbo Mode | Increases fan speed for faster dehumidification |
| Auto-Restart | Resumes previous settings after power outage |
| 24-Hour Timer | Program on/off cycles |
| Full Tank Alert | LED indicator and auto-shutoff when tank is full |
| Mobility | Four casters and top handle for easy movement |
| Power Cord | 6-foot length with storage wrap |
Unpack and inspect contents. Place on level, stable floor.
WARNING! Do not place near heat sources or in direct sunlight. Ensure room temperature is between 41°F and 95°F for optimal performance.
Power on dehumidifier; set initial preferences.
CAUTION! Handle water tank carefully to avoid spills. Do not operate without air filter installed.
Control Panel: POWER, HUMIDITY UP/DOWN, FAN SPEED (Normal/Turbo), TIMER SET, FILTER RESET indicator.
Display: Current humidity, target humidity, timer settings, filter alert, full tank indicator.
Humidity Setting: Adjust in 5% increments. Fan Speed: Normal for quiet operation, Turbo for maximum moisture removal. Timer: Set in 1-hour increments up to 24 hours. Filter Reset: Press and hold FILTER button for 3 seconds after cleaning filter. Auto-Defrost: Activates automatically in low temperatures to prevent coil freezing.
Standard, Continuous, and Timer modes available.
Tip: Use Continuous mode for initial drying of very damp spaces, then switch to Standard mode.
Unplug unit before any maintenance.
WARNING! Never immerse unit in water. Do not operate without filter.
Two methods: Manual (water tank) or Continuous (drain hose).
Manual Draining: Unit stops when tank is full (indicator lights). Remove tank, carry to drain, empty, replace.
Continuous Draining: Attach 5/8" ID hose to drain port. Ensure hose has downward slope without kinks. Unit will drain automatically without stopping.
CAUTION! For continuous drain, place unit near floor drain or sink. Check hose regularly for clogs.
UL Listed. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110. This product meets ENERGY STAR® guidelines for energy efficiency when used as directed.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power issue/full tank | Check power outlet; ensure tank is empty and properly seated; reset circuit breaker. |
| Reduced moisture removal | Dirty filter/extreme conditions | Clean air filter; ensure room temp is 41-95°F; check for blocked airflow. |
| Water leaking | Tank not seated/hose leak | Remove and reinsert tank; check hose connections; ensure unit is level. |
| Loud noise | Loose parts/obstruction | Ensure unit is on level surface; check for objects near fan; tighten any loose panels. |
| Display shows "FL" | Filter needs cleaning | Clean air filter, then press and hold FILTER button for 3 seconds to reset. |
| Frost on coils | Low temperature | Auto-defrost should activate; if persistent, move to warmer area or increase room temp. |
Reset: Unplug for 10 minutes, then restart.
Service: 1-800-332-1110; www.honeywellhome.com