Honeywell TP70P Dehumidifier Manual

The Honeywell TP70P is a high-capacity portable dehumidifier designed to remove excess moisture from the air in rooms up to a specified size. It features adjustable humidity control, continuous drainage option, auto-defrost function, washable air filter, full tank alert with auto-shutoff, and caster wheels for easy mobility. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Control Panel, Water Tank, Air Filter, Casters, Drain Hose Connector, Power Cord.

FeatureDescription
Humidity ControlAdjustable digital humidistat with auto mode
Water TankRemovable bucket with full indicator and auto-shutoff
Continuous DrainageHose connection for unattended operation
Auto DefrostProtects compressor in low temperatures
Washable FilterCaptures airborne particles; easy to clean
Turbo ModeHigh-speed moisture removal
24-Hour TimerProgrammable on/off cycles
MobilityFour caster wheels for easy movement
Control LockPrevents accidental setting changes
Power IndicatorLED shows unit status

Installation & Placement

Unpack and inspect contents. Place on a flat, stable surface.

  1. Positioning: Place unit in center of room, at least 12 inches from walls and furniture for proper airflow.
  2. Level Surface: Ensure unit is level to prevent water leakage.
  3. Ambient Temperature: Operate within specified temperature range (see Specifications).
  4. Power Connection: Plug directly into a grounded 120V AC outlet. Do not use extension cords.

WARNING! Do not place in tight enclosures or block air vents. Ensure room doors/windows are closed for optimal performance.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Install Filter: Ensure washable air filter is correctly seated in the front grille.
  2. Set Humidity Level: Press HUMIDITY button to set desired RH% (40-60% recommended).
  3. Select Mode: Choose AUTO, CONTINUOUS, or TURBO based on needs.
  4. Check Drainage: Decide between using water tank or connecting drain hose (see Drainage Options).

CAUTION! Allow unit to stand upright for 24 hours if it was tilted during transport before first use.

Specifications

Controls and Settings

Access functions via control panel or remote (if included). Front Panel: POWER, MODE, HUMIDITY, TIMER, TURBO, FILTER RESET.

Display Icons: Power, Tank Full, Defrost, Filter Alert, Lock, Humidity Setting, Timer.

Humidity Control: Set target humidity (35%-85%). Modes: AUTO (maintains set humidity), CONTINUOUS (runs constantly), TURBO (maximum dehumidification). Timer: Set 1-24 hours for automatic start/stop. Filter Reset: Press after cleaning filter to reset alert. Control Lock: Hold LOCK button for 3 seconds to disable panel.

Operation Modes

AUTO: Unit cycles on/off to maintain set humidity level. CONTINUOUS: Runs continuously until turned off or tank is full. TURBO: Runs fan at highest speed for fastest moisture removal.

  1. Press POWER to turn on.
  2. Press MODE to cycle through AUTO, CONTINUOUS, TURBO.
  3. In AUTO mode, use HUMIDITY buttons to set desired level.
  4. For timed operation, use TIMER to set shutdown or startup delay.

Tip: Use AUTO mode for energy efficiency. Use TURBO in very damp conditions, then switch to AUTO.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Water Tank: Empty regularly. Clean with mild detergent and rinse. Dry before reinserting.
  2. Air Filter: Clean every 2 weeks or as needed. Remove, rinse with water, let dry completely before reinstalling. Press FILTER RESET.
  3. Exterior: Wipe with soft, damp cloth. Do not use abrasive cleaners.
  4. Grille and Vents: Use vacuum brush attachment to remove dust.
  5. End-of-Season: Empty tank, clean filter, dry interior, coil and store in a dry place.

CAUTION! Never immerse unit in water. Do not operate without filter installed.

Drainage Options

Manual (Bucket): Unit stops when tank is full (Full light illuminates). Empty bucket and replace to resume.

Continuous: Connect standard garden hose (not included) to drain port. Ensure hose runs downward to floor drain or sink. Unit will operate continuously without stopping.

Note: For continuous drainage, ensure hose is not kinked and outlet is lower than drain port.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. This product meets applicable industry standards. Copyright and trademarks owned by Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Full tankCheck plug/power; empty water tank; ensure filter is clean.
Little or no water collectionLow humidity / Cold roomCheck room humidity; ensure room temp is above 41°F (5°C).
Unit runs but stops frequentlyAuto-defrost cycle / Full tankNormal in cold conditions; check tank level.
Loud or unusual noiseLoose parts / Dirty filterEnsure unit is level; clean air filter; check for obstructions.
Error code on displaySensor / System faultUnplug for 10 minutes, then restart. If persists, contact service.
Water leakageImproper hose connection / Tank not seatedCheck drain hose; ensure tank is correctly inserted and unit is level.

Reset: Unplug unit for 10 minutes to reset control system.

Service: 1-800-474-2147; www.honeywellhome.com