The Honeywell TP70AWKN is a 70-pint capacity dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drain option, washable filter, auto-restart after power interruption, full tank alert with auto-shutoff, turbo mode for faster dehumidification, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Dehumidifier unit with built-in humidistat, removable water tank, washable air filter, control panel, continuous drain hose connection, casters for mobility, and handle for transport.
| Feature | Description |
|---|---|
| Capacity | 70 pints per day (at 60°F, 60% RH) |
| Humidistat | Automatic humidity control (30%-80% RH) |
| Water Tank | Removable 1.8-gallon bucket with full indicator |
| Continuous Drain | Hose connection for unattended operation |
| Air Filter | Washable mesh filter for dust and particles |
| Turbo Mode | High-speed dehumidification |
| Auto Restart | Resumes previous settings after power loss |
| Auto Shutoff | Stops operation when tank is full |
| Control Panel | Digital display with humidity readout |
| Mobility | Four casters and carrying handle |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place in tight enclosures or near heat sources. Ensure proper ventilation.
Power on dehumidifier; follow initial setup steps.
CAUTION! Handle water tank carefully when full to prevent spills.
Control Panel: POWER button, HUMIDITY +/- buttons, MODE selector, FILTER indicator, TANK FULL indicator.
Display: Current humidity level, set point, mode indicator, filter alert, tank full alert.
Humidity Setting: Press HUMIDITY + or - to adjust between 30%-80% RH. Mode Selection: AUTO (maintains set humidity), TURBO (maximum dehumidification), CONTINUOUS (runs continuously regardless of humidity). Timer: 1-24 hour programmable timer (press TIMER button). Filter Reset: Press and hold FILTER button for 3 seconds after cleaning.
AUTO Mode: Unit cycles on/off to maintain set humidity level. TURBO Mode: Runs compressor and fan at maximum speed for rapid dehumidification. CONTINUOUS Mode: Operates continuously until manually turned off or tank is full.
Tip: For energy efficiency, use AUTO mode with humidity set to 45%-50%.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug unit before cleaning or maintenance.
Two drainage methods: Manual (water tank) or Continuous (hose).
Water Tank: Remove tank when full indicator lights; empty and replace. Continuous Drain: Attach 5/8" ID hose to drain port; ensure downward slope for gravity flow.
CAUTION! Do not operate without tank or proper hose connection.
Auto Shutoff: Stops operation when tank is full. Overload Protection: Prevents motor damage from power surges. Anti-Frost Sensor: Protects compressor in low temperatures. Child Lock: Prevents accidental setting changes.
UL Listed: Meets safety standards for household dehumidifiers. Energy Star: Compliant with energy efficiency guidelines. EPA Refrigerant: Uses R-410a environmentally friendly refrigerant. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not turning on | Power issue | Check power outlet; ensure plug is secure; test outlet with another device. |
| Not removing moisture | Settings/filter | Check humidity setting; clean filter; ensure room temperature above 41°F. |
| Water leaking | Tank/drain issue | Ensure tank properly seated; check drain hose connection; clean drain port. |
| Loud noise | Vibration/obstruction | Place on level surface; check for objects near fan; tighten components. |
| Filter light on | Dirty filter | Clean filter as instructed; press and hold FILTER button to reset. |
| Ice on coils | Low temperature | Turn off unit; allow ice to melt; increase room temperature above 41°F. |
| Poor airflow | Blocked vents | Clear obstructions from intake and exhaust; clean filter. |
Reset: Unplug for 5 minutes, then restart. For persistent issues, contact support.