Honeywell TP50WKN Dehumidifier Manual

The Honeywell TP50WKN is a 50-pint capacity dehumidifier designed for medium to large rooms up to 3000 sq. ft. It features adjustable humidity control (35%-85%), continuous drain option, auto-defrost for low-temperature operation, washable air filter, full bucket alert with auto shut-off, 24-hour timer, turbo mode for faster moisture removal, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control panel with digital display, Water collection bucket, Washable air filter, Continuous drain hose connection, Casters for mobility, Handle for transport.

FeatureDescription
Humidity ControlAdjustable from 35% to 85% relative humidity
Water Bucket Capacity1.6 gallon (6 liter) removable bucket
Continuous DrainGarden hose connection for automatic drainage
Auto DefrostPrevents coil freezing in temperatures down to 41°F (5°C)
Turbo ModeHigh-speed fan for maximum moisture removal
24-Hour TimerProgrammable on/off scheduling
Full Bucket AlertIndicator light and auto shut-off when bucket is full
Filter Check AlertReminder to clean the washable air filter
Energy EfficiencyEnergy Star certified for reduced power consumption
Mobility FeaturesFour casters and top carry handle

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Clear area: Ensure at least 12-18 inches of clearance on all sides for proper airflow.
  2. Check flooring: Place on waterproof surface if using continuous drain.
  3. Position near drain: If using hose drainage, position within 6 feet of floor drain.
  4. Avoid extreme temperatures: Keep away from direct sunlight, heat sources, or freezing conditions.
  5. Install casters: Attach all four wheels if not pre-installed.

WARNING! Do not operate in temperatures below 41°F (5°C) unless auto-defrost is active. Ensure unit is upright for at least 24 hours before first use if transported on its side.

First-Time Setup

Plug into grounded 115V outlet; follow initial setup steps.

  1. Bucket installation: Insert empty water bucket completely until it clicks.
  2. Filter check: Remove and inspect washable filter; reinstall properly.
  3. Power on: Press POWER button; unit will start in last used settings.
  4. Set humidity level: Use UP/DOWN buttons to select desired humidity (recommended 45-50%).
  5. Select mode: Choose between Normal, Turbo, or Timer mode based on needs.
  6. Test operation: Allow unit to run for 15 minutes to ensure proper condensation.

CAUTION! Always use grounded outlet. Do not use extension cords. Ensure bucket is properly seated before operation.

Specifications

Controls and Settings

Control Panel Features: Digital display, POWER button, MODE selector, HUMIDITY adjust, TIMER set, FILTER reset.

Display Indicators: Current humidity, Set humidity, Timer status, Filter alert, Full bucket alert, Defrost mode, Turbo mode.

Humidity Control: Adjust between 35%-85% in 5% increments. Modes: Normal (standard operation), Turbo (maximum dehumidification), Continuous (runs until bucket full/turned off). Timer: Program 1-24 hours for automatic start/stop. Filter Alert: Flashing indicator after 250 hours of operation. Bucket Full: Red light and auto shut-off when bucket reaches capacity.

Operation Modes

Normal Mode: Standard dehumidification with balanced fan speed and energy use. Turbo Mode: Maximum moisture removal with high fan speed for rapid drying. Continuous Mode: Maintains set humidity level without automatic shut-off (requires drain hose). Timer Mode: Set 1-24 hour operation schedule.

  1. Select mode: Press MODE button to cycle through options.
  2. Set humidity: Use UP/DOWN arrows to desired level (40-50% recommended for home use).
  3. Monitor display: Current room humidity shows on left, set point on right.
  4. Adjust as needed: Increase humidity setting in dry conditions, decrease in damp conditions.

Tip: Use Turbo mode initially in very damp spaces, then switch to Normal mode for maintenance.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Daily: Check water bucket; empty when full or when alert light activates.
  2. Weekly: Clean air filter - remove, wash with mild detergent, rinse, dry completely before reinstalling.
  3. Monthly: Clean exterior with soft, damp cloth; never use harsh chemicals.
  4. Seasonally: Deep clean coils and interior with compressed air or soft brush.
  5. Annually: Check drain hose for clogs if using continuous drainage.

WARNING! Always unplug unit before cleaning. Never immerse in water. Do not operate without air filter installed.

Drainage Options

Bucket Drainage: Standard method using removable bucket. Continuous Drainage: Using included hose for automatic water removal.

  1. For bucket use: Ensure bucket properly seated; empty when full indicator lights.
  2. For hose drainage: Remove bucket, attach garden hose to drain port (not included), route to floor drain or outside.
  3. Gravity drain: Ensure hose runs downward without kinks or loops.
  4. Check connection: Ensure hose is securely attached to prevent leaks.

CAUTION! Do not lift unit with water in bucket. Empty bucket before moving. Ensure continuous drain hose is properly installed to prevent water damage.

Care & Storage

Off-season storage preparation and general care instructions.

  1. Clean thoroughly: Wash bucket and filter, dry completely.
  2. Drain residual water: Run in fan-only mode for 2 hours to dry internal components.
  3. Coil protection: Cover coils with plastic bag to prevent dust accumulation.
  4. Store properly: Keep in dry, temperature-controlled area, upright position.
  5. Cord storage: Wrap power cord around cord hooks on back of unit.

CAUTION! Never store with water in bucket. Do not cover air intake/exhaust vents during storage. Store in area protected from pests.

Regulatory Information

FCC Compliance: This device complies with Part 15 of FCC Rules. Energy Star: Certified to meet energy efficiency guidelines. EPA Refrigerant Management: Compliant with Section 608 of Clean Air Act. UL Listed: Meets safety standards UL 474. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not powering onPower source/connectionCheck outlet; ensure plug fully inserted; test outlet with another device.
Not removing moistureTemperature/filter/settingsCheck room temp (41-95°F); clean filter; lower humidity setting; ensure doors/windows closed.
Water leakingBucket placement/hoseEnsure bucket fully seated; check hose connections; level unit on floor.
Loud or unusual noiseForeign objects/fanCheck for obstructions; ensure unit level; contact service if internal noise persists.
Display shows error codeSensor/system issueUnplug for 5 minutes, restart; if persists, note code and contact support.
Fan runs but no dehumidificationLow temperature/refrigerantCheck room temperature; wait for auto-defrost cycle; contact service if issue continues.
Filter light flashingMaintenance requiredClean air filter; press and hold FILTER button for 3 seconds to reset.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-332-1110; www.honeywellhome.com

Honeywell TP50WKN Dehumidifier Manual © - All Rights Reserved 2025