The Honeywell TP50AWKNR is a 50-pint capacity dehumidifier designed for medium to large rooms, featuring an Energy Star rating, digital humidistat, continuous drain option, auto defrost, washable filter, full tank alert with auto shut-off, and caster wheels for mobility. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital control panel, 50-pint water tank, washable air filter, continuous drain hose connection, caster wheels, humidistat, and auto defrost function.
| Feature | Description |
|---|---|
| Capacity | Removes up to 50 pints of moisture per day (at 80°F, 60% RH) |
| Digital Humidistat | Allows precise humidity level setting (30% - 80%) |
| Continuous Drain Option | Hose connection for unattended operation |
| Auto Defrost | Prevents coil freezing in low temperatures |
| Washable Filter | Captures airborne particles; reusable |
| Full Tank Alert & Auto Shut-off | Indicator light and automatic power-off when tank is full |
| Caster Wheels | Four wheels for easy mobility |
| Energy Star Rated | Energy efficient operation |
| Timer Function | Programmable 2/4/8 hour timer |
| Turbo Mode | High-speed dehumidification |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place in tight enclosures or block air vents. Ensure power cord is not pinched or damaged.
Plug into dedicated 115V AC outlet; follow initial setup steps.
CAUTION! Handle water tank with care; empty before moving unit.
Access controls via digital panel on top of unit. Front Panel: POWER, MODE, HUMIDITY, TIMER, TURBO, FILTER RESET.
Control Functions: POWER turns unit on/off. MODE cycles through Continuous, Auto. HUMIDITY adjusts set point. TIMER sets 2/4/8 hour delay. TURBO activates high-speed drying. FILTER RESET resets filter maintenance indicator.
Settings: Humidity level (30-80%), Mode (Continuous runs until tank full; Auto maintains set humidity), Timer (delayed start/stop), Turbo (increases fan speed), Filter Alert (lights when cleaning needed).
Auto Mode: Unit runs until set humidity is reached, then cycles on/off to maintain. Continuous Mode: Runs constantly until tank is full or power is off. Turbo Mode: Maximum moisture removal for rapid drying.
Tip: In damp conditions, start with Turbo mode, then switch to Auto.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug unit before cleaning. Do not immerse in water.
If not using for extended period (e.g., winter), prepare unit for storage.
CAUTION! Do not store with water in tank or lines to prevent mold/mildew.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that it does not cause harmful interference. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147. Energy Star is a registered trademark of the U.S. EPA.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not turning on | No power | Check outlet; ensure plug is secure; test outlet with another device. |
| Not removing moisture | Room temp too low/high, filter dirty | Ensure room temp is between 41°F-90°F; clean filter; check humidity setting. |
| Water leaking | Tank not seated, drain hose issue | Ensure tank is properly inserted; check hose for leaks/kinks. |
| Loud or unusual noise | Loose parts, fan obstruction | Ensure unit is level; check for objects near fan; contact service if persistent. |
| Filter light on | Filter needs cleaning | Clean filter as instructed; press and hold FILTER RESET for 3 seconds. |
| Frost on coils | Low temperature operation | Auto defrost should activate; move to warmer area if below 41°F. |
Reset: Unplug for 5 minutes, then restart.
Service: 1-800-474-2147; www.honeywellhome.com