Honeywell TP50AWKN Dehumidifier Manual

The Honeywell TP50AWKN is a 50-pint capacity dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drainage option, washable air filter, auto-restart after power interruption, full tank alert with auto-shutoff, turbo mode for faster dehumidification, and 24-hour timer. Ideal for basements, living areas, and other spaces up to 3000 sq ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Safety Information 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Dehumidification unit with 50-pint capacity, Control Panel, Washable Filter, Water Tank, Continuous Drain Hose Connection, Casters for mobility, Handle for transport.

FeatureDescription
Humidity ControlAutomatic humidity sensing with adjustable setpoint (35-85% RH)
Water TankRemovable 1.8-gallon bucket with full indicator and auto-shutoff
Continuous DrainGarden hose connection for unattended operation
Air FilterWashable mesh filter for improved air quality
Turbo ModeHigh-speed dehumidification for maximum moisture removal
Timer Function24-hour programmable on/off timer
Auto-RestartResumes previous settings after power interruption
Control LockPrevents accidental setting changes
MobilityFour swivel casters and top carry handle
Display PanelDigital display showing humidity level and settings

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room away from walls/furniture for optimal airflow.
  2. Check clearance: Maintain at least 12 inches clearance on all sides.
  3. Level surface: Ensure unit is level for proper water collection.
  4. Connect power: Plug into dedicated 115V AC outlet (do not use extension cord).
  5. Setup drainage: For continuous operation, attach garden hose to drain port.

WARNING! Do not place in areas below 41°F (5°C). Ensure proper ventilation around unit.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Insert water tank: Ensure tank is properly seated and locked in place.
  2. Set humidity level: Press HUMIDITY button to select desired RH percentage (45-50% recommended).
  3. Choose mode: Select AUTO for automatic operation or TURBO for maximum dehumidification.
  4. Set timer (optional): Press TIMER to program automatic on/off schedule.
  5. Check filter: Verify filter is clean before first use.

CAUTION! Allow unit to stand upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Control Panel: POWER, MODE (Auto/Turbo), HUMIDITY (+/-), TIMER, FILTER ALERT, LOCK.

Display Indicators: Current humidity, Set humidity, Timer status, Filter alert, Full tank, Turbo mode.

Humidity Control: Adjust between 35-85% RH in 5% increments. Timer: Program 1-24 hours for automatic on/off. Mode Selection: AUTO (maintains set humidity), TURBO (maximum dehumidification). Filter Alert: Illuminates when filter needs cleaning. Control Lock: Press and hold LOCK for 3 seconds to disable buttons.

Operation Modes

Auto Mode: Unit runs only when humidity exceeds set point. Turbo Mode: Continuous operation at maximum capacity.

  1. For normal use: Select AUTO mode with humidity set to 45-50%.
  2. For rapid drying: Select TURBO mode for maximum moisture removal.
  3. For continuous drainage: Connect hose to drain port; unit will run continuously.
  4. For scheduled operation: Use timer to run during specific hours.

Tip: Close windows and doors for most efficient operation.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean filter: Remove and wash filter every 2 weeks or when FILTER light illuminates.
  2. Empty water tank: Check regularly; empty when FULL indicator lights.
  3. Clean exterior: Wipe with damp cloth; do not use harsh chemicals.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Clean coils: Vacuum condenser coils every 3 months during heavy use.

WARNING! Always unplug unit before cleaning. Allow filter to dry completely before reinstalling.

Storage & Winterization

Proper storage prevents damage during non-use periods.

  1. Clean unit thoroughly following maintenance instructions.
  2. Empty and dry water tank completely.
  3. Run in FAN ONLY mode for 30 minutes to dry internal components.
  4. Store in upright position in dry, protected area.
  5. Cover unit to prevent dust accumulation.

CAUTION! Do not store in temperatures below freezing.

Safety Information

Important safety precautions for proper operation.

Regulatory Information

UL Listed: Meets UL 474 safety standards. Energy Star: Certified for energy efficiency. EPA: Compliant with refrigerant regulations. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110. Model TP50AWKN covered by 1-year limited warranty.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/tank fullCheck power connection; empty water tank; ensure tank is properly seated.
Poor dehumidificationFilter dirty/room too coldClean filter; ensure room temperature above 41°F; check for air blockage.
Water leakingTank not seated/hose connectionEnsure tank is properly installed; check drain hose for leaks/kinks.
Loud operationUneven surface/fan issuePlace on level surface; check for obstructions in fan area.
Display not workingPower interruptionUnplug for 1 minute, then reconnect; check circuit breaker.
Ice on coilsLow temperatureTurn off unit; allow ice to melt; move to warmer location.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-332-1110; www.honeywellhome.com

Honeywell TP50AWKN Dehumidifier Manual © - All Rights Reserved 2025