The Honeywell TP30WK is a 30-pint portable dehumidifier designed for medium-sized rooms up to 1500 sq. ft. It features an automatic humidistat, continuous drain option, auto-defrost, washable filter, full tank alert with auto-shutoff, and energy-efficient operation. Ideal for basements, bathrooms, and living areas to reduce moisture and prevent mold/mildew. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Portable cabinet with handle and casters, Water tank with handle, Control panel with digital display, Air filter, Drain hose connector, Power cord.
| Feature | Description |
|---|---|
| Capacity | Removes up to 30 pints per day (at 80°F, 60% RH) |
| Automatic Humidistat | Maintains desired humidity level (30%-80% RH) |
| Continuous Drain Option | Gravity drain hose connection for unattended operation |
| Auto-Defrost | Protects compressor in low temperatures |
| Full Tank Alert & Auto-Shutoff | Light indicator and automatic shutoff when tank is full |
| Washable Air Filter | Captures dust and particles; reusable |
| Digital Controls | Humidistat setting, fan speed (High/Low), timer |
| Portable Design | Built-in handles and casters for easy mobility |
| Energy Efficient | ENERGY STAR® certified |
| Quiet Operation | Low noise level for residential use |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place in tight enclosures or near heat sources. Ensure unit is upright during operation.
Plug into power outlet; follow initial setup steps.
CAUTION! Allow unit to sit upright for 24 hours if transported horizontally to stabilize refrigerant.
Control Panel: POWER button, Humidity setting buttons, Fan Speed button, Timer button, Filter Reset indicator, Full Tank indicator.
Display: Current humidity, Set humidity, Fan speed icon, Timer status, Filter alert, Full tank alert.
Humidity Setting: Press UP/DOWN to adjust target RH (30%-80%). Fan Speed: Press FAN to toggle between HIGH and LOW. Timer: Press TIMER to set 1-24 hour ON/OFF delay. Filter Alert: LED lights when filter needs cleaning. Auto-Restart: Unit resumes previous settings after power outage.
Normal Mode: Runs until target humidity is reached, then cycles on/off. Continuous Mode: Runs continuously regardless of humidity (press and hold HUMIDITY for 3 sec). Laundry Mode: High-speed dehumidification for drying laundry indoors (press and hold FAN for 3 sec).
Tip: Close windows and doors for optimal efficiency. Use in temperatures above 41°F.
Unplug unit before maintenance.
CAUTION! Do not immerse unit in water. Never operate without filter.
Manual Drainage: Use removable tank; empty when FULL light comes on. Continuous Drainage: Attach 5/8" ID hose (not included) to drain port; route hose to floor drain or sink.
Note: Ensure hose is securely attached to prevent leaks.
FCC Part 15: Class B digital device; complies with interference limits for residential use. ENERGY STAR® certified. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147. This product contains refrigerant; dispose of according to local regulations.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not turning on | No power | Check outlet; ensure plug is secure; test outlet with another device. |
| Little or no water collection | Low humidity, cold temps, clogged filter | Check room humidity; ensure temp >41°F; clean filter; check airflow. |
| Full tank light on but tank not full | Tank not seated properly | Remove and reinstall tank; check for obstructions. |
| Unit runs continuously | Set humidity too low, continuous mode on | Adjust humidity setting; check if continuous mode is activated. |
| Unusual noise | Loose parts, debris in fan | Ensure unit is level; check for objects near fan; contact service if internal noise. |
| Error code "E1" | Sensor fault | Unplug for 10 minutes, restart; if persists, contact service. |
| Error code "E2" | Full tank sensor fault | Check tank position; clean sensor area; reset unit. |
Reset: Unplug for 10 minutes, then restart.
Service: 1-800-474-2147; www.honeywellhome.com