Honeywell TP30WK Dehumidifier Manual

The Honeywell TP30WK is a 30-pint portable dehumidifier designed for medium-sized rooms up to 1500 sq. ft. It features an automatic humidistat, continuous drain option, auto-defrost, washable filter, full tank alert with auto-shutoff, and energy-efficient operation. Ideal for basements, bathrooms, and living areas to reduce moisture and prevent mold/mildew. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Portable cabinet with handle and casters, Water tank with handle, Control panel with digital display, Air filter, Drain hose connector, Power cord.

FeatureDescription
CapacityRemoves up to 30 pints per day (at 80°F, 60% RH)
Automatic HumidistatMaintains desired humidity level (30%-80% RH)
Continuous Drain OptionGravity drain hose connection for unattended operation
Auto-DefrostProtects compressor in low temperatures
Full Tank Alert & Auto-ShutoffLight indicator and automatic shutoff when tank is full
Washable Air FilterCaptures dust and particles; reusable
Digital ControlsHumidistat setting, fan speed (High/Low), timer
Portable DesignBuilt-in handles and casters for easy mobility
Energy EfficientENERGY STAR® certified
Quiet OperationLow noise level for residential use

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room or area with high humidity, away from walls/furniture (at least 12-18 inches clearance).
  2. Ensure proper airflow: Keep air inlet and outlet grilles unobstructed.
  3. Check power: Use grounded 120V AC outlet; avoid extension cords.
  4. Install drain hose (optional): Attach to drain port for continuous drainage.

WARNING! Do not place in tight enclosures or near heat sources. Ensure unit is upright during operation.

First-Time Setup

Plug into power outlet; follow initial setup steps.

  1. Install water tank: Slide empty tank into base until it clicks.
  2. Power on: Press POWER button; unit will start in default mode.
  3. Set desired humidity: Use UP/DOWN buttons to set target RH (recommended 45-50%).
  4. Select fan speed: Choose HIGH for faster dehumidification or LOW for quiet operation.
  5. Set timer (optional): Program ON/OFF timer for automatic operation.

CAUTION! Allow unit to sit upright for 24 hours if transported horizontally to stabilize refrigerant.

Specifications

Controls and Settings

Control Panel: POWER button, Humidity setting buttons, Fan Speed button, Timer button, Filter Reset indicator, Full Tank indicator.

Display: Current humidity, Set humidity, Fan speed icon, Timer status, Filter alert, Full tank alert.

Humidity Setting: Press UP/DOWN to adjust target RH (30%-80%). Fan Speed: Press FAN to toggle between HIGH and LOW. Timer: Press TIMER to set 1-24 hour ON/OFF delay. Filter Alert: LED lights when filter needs cleaning. Auto-Restart: Unit resumes previous settings after power outage.

Operation Modes

Normal Mode: Runs until target humidity is reached, then cycles on/off. Continuous Mode: Runs continuously regardless of humidity (press and hold HUMIDITY for 3 sec). Laundry Mode: High-speed dehumidification for drying laundry indoors (press and hold FAN for 3 sec).

  1. Select mode via control panel.
  2. Monitor current humidity on display.
  3. Empty water tank when FULL light illuminates (or use continuous drain).

Tip: Close windows and doors for optimal efficiency. Use in temperatures above 41°F.

Maintenance & Cleaning

Unplug unit before maintenance.

  1. Clean air filter: Remove filter every 2 weeks; rinse with warm water, air dry completely before reinstalling.
  2. Empty and clean water tank: Empty tank regularly; clean with mild detergent and soft cloth.
  3. Clean exterior: Wipe cabinet with damp cloth; do not use abrasive cleaners.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Off-season storage: Empty tank, clean unit, coil drain hose, store upright in dry location.

CAUTION! Do not immerse unit in water. Never operate without filter.

Drainage Options

Manual Drainage: Use removable tank; empty when FULL light comes on. Continuous Drainage: Attach 5/8" ID hose (not included) to drain port; route hose to floor drain or sink.

  1. For continuous drain: Remove tank, connect hose to rear port, ensure downward slope.
  2. Unit will operate continuously; tank can remain installed but will not fill.

Note: Ensure hose is securely attached to prevent leaks.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. ENERGY STAR® certified. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147. This product contains refrigerant; dispose of according to local regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is secure; test outlet with another device.
Little or no water collectionLow humidity, cold temps, clogged filterCheck room humidity; ensure temp >41°F; clean filter; check airflow.
Full tank light on but tank not fullTank not seated properlyRemove and reinstall tank; check for obstructions.
Unit runs continuouslySet humidity too low, continuous mode onAdjust humidity setting; check if continuous mode is activated.
Unusual noiseLoose parts, debris in fanEnsure unit is level; check for objects near fan; contact service if internal noise.
Error code "E1"Sensor faultUnplug for 10 minutes, restart; if persists, contact service.
Error code "E2"Full tank sensor faultCheck tank position; clean sensor area; reset unit.

Reset: Unplug for 10 minutes, then restart.

Service: 1-800-474-2147; www.honeywellhome.com