The Honeywell TP30AWKNR is a 30-pint capacity dehumidifier designed for medium-sized rooms up to 1500 sq. ft. It features automatic humidity control, continuous drain option, washable filter, auto-restart, turbo mode, and a digital display with humidity readout. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital control panel, washable air filter, removable water tank with handle and full-tank indicator, continuous drain hose connection, casters for mobility.
| Feature | Description |
|---|---|
| Capacity | 30 pints per day (at 80°F, 60% RH) |
| Coverage Area | Up to 1500 sq. ft. |
| Humidity Control | Auto humidity control (35%-85% RH) |
| Digital Display | Current humidity level and settings |
| Water Tank | Removable 1.8-gallon tank with full indicator |
| Continuous Drain | Hose connection for continuous operation |
| Washable Filter | Captures airborne particles |
| Turbo Mode | Maximum moisture removal |
| Auto Restart | Resumes previous settings after power outage |
| Timer | 24-hour on/off timer |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure proper ventilation around unit.
Power on dehumidifier; follow initial setup steps.
CAUTION! Handle water tank carefully to avoid spills. Ensure unit is level.
Control Panel: POWER, MODE, HUMIDITY, TIMER, TURBO, FILTER RESET.
Display Indicators: Current humidity, set humidity, full tank, filter clean, turbo mode, timer.
Humidity Setting: Press HUMIDITY to set target humidity (35%-85%). Mode Selection: AUTO (maintains set humidity), CONTINUOUS (runs continuously), TURBO (maximum dehumidification). Timer: 24-hour programmable on/off timer. Filter Reset: Press after cleaning filter to reset indicator.
AUTO Mode: Automatically cycles to maintain set humidity level. CONTINUOUS Mode: Runs continuously regardless of humidity. TURBO Mode: Maximum fan speed for fastest dehumidification.
Tip: For best energy efficiency, use AUTO mode with humidity set to 45-50%.
Unplug before maintenance. Clean every 2 weeks during heavy use.
WARNING! Do not immerse unit in water. Ensure filter is completely dry before reinstalling.
Manual Drainage: Use removable water tank; empty when full indicator lights. Continuous Drainage: Connect 5/8" ID hose to drain port for unattended operation.
CAUTION! Ensure proper drainage to prevent water damage. Check hose regularly for clogs.
UL Listed: Meets safety standards for household use. Energy Star: Meets energy efficiency guidelines. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not running | Power issue/full tank | Check power connection; empty water tank; reset circuit breaker. |
| Poor dehumidification | Room too cold/filter dirty | Ensure room temperature above 41°F; clean air filter. |
| Water leaking | Tank not seated/hose issue | Ensure tank properly installed; check drain hose connections. |
| Loud noise | Uneven surface/fan issue | Place on level surface; check for obstructions in fan. |
| Display not working | Power issue | Check power source; unplug for 10 minutes then restart. |
Reset: Unplug for 10 minutes to reset electronic controls.
Service: 1-800-474-2147; www.honeywellhome.com