Honeywell TP30AWKN Dehumidifier Manual

The Honeywell TP30AWKN is a 30-pint portable dehumidifier designed for medium-sized rooms up to 1500 sq. ft. It features automatic humidity control, a continuous drain option, a full-bucket alert with auto-shutoff, a washable filter, a digital display, and a 24-hour timer. Ideal for basements, bathrooms, and living areas to reduce moisture, prevent mold, and improve air quality. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, 30-pint water bucket, washable air filter, continuous drain hose connection, casters for mobility, and humidity sensor.

FeatureDescription
Digital DisplayShows current humidity, mode, timer, and alerts
Automatic Humidity ControlSet desired humidity level (35%-85%)
Continuous Drain OptionConnect hose for unattended operation
Full-Bucket Alert & Auto-ShutoffLight indicator and automatic power-off when bucket is full
24-Hour TimerProgram on/off cycles
Washable Air FilterRemoves airborne particles; clean every 2 weeks
Portable DesignBuilt-in handles and casters for easy movement
Turbo ModeMaximum moisture removal for high humidity
Sleep ModeQuiet operation with dimmed display
Power Cord StorageIntegrated wrap for neat storage

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room or area with high humidity, away from walls/furniture (min 12-18 inches clearance).
  2. Check airflow: Ensure air intake and exhaust vents are unobstructed.
  3. Install drain hose (optional): Attach to drain port and route to floor drain or sink.
  4. Insert water bucket: Slide bucket into unit until it clicks into place.
  5. Plug into grounded 120V AC outlet.

WARNING! Do not use in temperatures below 41°F (5°C). Ensure unit is upright before operating.

First-Time Setup

Power on dehumidifier; follow control panel prompts.

  1. Set language: Press MENU, select ENGLISH (default).
  2. Set target humidity: Use UP/DOWN buttons to choose between 35% and 85% RH.
  3. Choose mode: Select AUTO (recommended), TURBO, or SLEEP.
  4. Set timer (optional): Program start/stop times in TIMER menu.
  5. Check filter: Ensure washable filter is clean and properly installed.

CAUTION! Allow unit to stand upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Access settings via digital control panel. Front Panel: POWER, MODE, TIMER, UP/DOWN, FILTER RESET.

Display Icons: Power, Bucket Full, Filter Clean, Turbo, Sleep, Timer, Humidity Level.

Humidity Control: Set target humidity (35%-85%). Modes: AUTO (maintains set humidity), TURBO (max dehumidification), SLEEP (quiet, dim display). Timer: Set 1-24 hours for automatic on/off. Filter Reset: Press after cleaning filter to reset reminder. Continuous Drain: Activate in menu when hose is connected.

Operating Modes

Auto Mode: Unit runs until target humidity is reached, then cycles on/off automatically. Turbo Mode: Runs continuously at high fan speed for fastest moisture removal. Sleep Mode: Reduces fan speed and dims display for nighttime operation.

  1. Press POWER to turn on.
  2. Press MODE to cycle through AUTO, TURBO, SLEEP.
  3. Use UP/DOWN to adjust target humidity.
  4. Monitor bucket: Empty when FULL light illuminates (auto-shutoff activates).
  5. For continuous drain: Connect hose, select DRAIN mode in menu.

Tip: Close windows and doors in room for optimal performance.

Maintenance & Cleaning

Unplug unit before maintenance.

  1. Empty bucket: Remove, pour out water, reinsert securely.
  2. Clean filter every 2 weeks: Remove, wash with warm water and mild detergent, air dry completely.
  3. Reset filter light: Press FILTER RESET after cleaning.
  4. Clean exterior: Wipe with soft, damp cloth; do not use harsh chemicals.
  5. Clean condenser coils annually: Use soft brush or vacuum with brush attachment.
  6. Check drain hose: Ensure it’s clear of clogs if using continuous drain.

WARNING! Do not operate without filter. Never immerse unit in water.

Storage & Winterization

If storing for extended period (e.g., winter):

  1. Unplug unit and empty bucket completely.
  2. Clean filter and let dry.
  3. Run in FAN mode for 30 minutes to dry internal components.
  4. Coil power cord and store in dry, covered area above 41°F.
  5. Cover unit to prevent dust accumulation.

CAUTION! Store upright. Do not place heavy objects on top.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. EPA Energy Star Certified. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is secure; test outlet with another device.
Not removing moistureRoom temp too low/high, filter dirtyEnsure room temp is 41°F-95°F; clean filter; close windows/doors.
Bucket full light on (but empty)Bucket not seated properlyRemove and reinsert bucket until click is heard.
Water leakingBucket misaligned, drain hose looseRe-seat bucket; check hose connection; ensure unit is level.
Loud or unusual noiseLoose parts, fan obstructionEnsure unit is on level surface; check for objects near fan; contact service if noise persists.
Display not workingPower issueUnplug for 1 minute, then restart; check circuit breaker.

Reset: Unplug for 10 minutes, then restart.

Service: 1-800-332-1110; www.honeywellhome.com

Honeywell TP30AWKN Dehumidifier Manual © - All Rights Reserved 2025