Honeywell TP-FIT-D-WK Dehumidifier Manual

The Honeywell TP-FIT-D-WK is a portable dehumidifier designed to remove excess moisture from the air in rooms up to a specified size. It features adjustable humidity control, automatic shut-off, a continuous drain option, a washable filter, and a water collection tank with a full-tank indicator. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Safety Information 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control Panel, Water Tank, Washable Air Filter, Casters for Mobility, Continuous Drain Hose Port, Handle for Carrying.

FeatureDescription
Humidity ControlAdjustable digital or dial control to set desired room humidity level
Automatic Shut-OffTurns off when water tank is full; indicator light illuminates
Continuous Drain OptionPort for connecting a hose (not included) for continuous drainage
Washable FilterRemovable and washable air filter to maintain airflow and air quality
Water TankRemovable tank with carry handle and full-tank indicator
Portable DesignBuilt-in handle and casters for easy movement between rooms
Timer FunctionOptional 24-hour timer to schedule operation (on select models)
Defrost FunctionAuto-defrost cycle for operation in cooler temperatures
Control LockFeature to lock current settings (on select models)
Power Cord StorageCompartment or wrap for neat cord storage

Installation & Placement

Unpack and inspect contents. Place on a flat, stable, and level surface.

  1. Choose Location: Place in the center of the room or area with excess moisture, away from walls and furniture for proper airflow.
  2. Check Clearance: Ensure at least 12-18 inches of clearance on all sides, especially the air intake and exhaust.
  3. Level Surface: Ensure unit is level so the internal bucket sits correctly and the full-tank sensor works properly.
  4. Ambient Temperature: Operate within the specified temperature range (typically above 41°F/5°C) for optimal performance.

WARNING! Do not place in tight enclosures or block air vents. Ensure the power cord is not pinched or damaged.

First-Time Setup

Before first use, prepare the dehumidifier.

  1. Install the Filter: Ensure the washable filter is correctly seated in its slot.
  2. Insert Water Tank: Push the empty water tank firmly into place until it clicks.
  3. Power Connection: Plug the power cord directly into a grounded 120V AC outlet. Do not use an extension cord.
  4. Initial Settings: Turn the unit on. Set your desired humidity level (start with 50% RH). Select fan speed if applicable.
  5. Allow Runtime: Let the unit run for 24 hours continuously to assess the moisture removal rate in your space.

CAUTION! Always handle the water tank with care to avoid spills. Empty the tank before moving the unit.

Specifications

Controls and Settings

Access controls via the front panel or digital display. Common Controls: POWER, HUMIDITY SET (+/-), FAN SPEED, MODE, TIMER, FILTER RESET.

Display Indicators: Power On, Target Humidity, Current Humidity, Full Tank, Filter Clean, Defrost Mode, Timer Set.

Humidity Control: Set desired relative humidity (RH) between 35% and 85%. Fan Speed: Select LOW for quiet operation, HIGH for maximum moisture removal. Mode: Continuous mode runs until tank is full/turned off; Auto mode cycles to maintain set humidity. Timer: Program to turn ON or OFF after a set number of hours. Filter Reset: Press after cleaning the air filter to reset the maintenance reminder.

Operation Modes

Auto Mode: Unit runs until set humidity is reached, then fan may run without compressor to circulate air. Continuous Mode: Runs compressor and fan continuously until tank is full or unit is turned off. Laundry Mode (if available): Runs at high fan speed for a set period to dry laundry in a closed room.

  1. Press POWER to turn on.
  2. Use HUMIDITY buttons to set your desired moisture level.
  3. Press FAN to select speed.
  4. Press MODE to choose between Auto and Continuous operation.
  5. Monitor the current humidity reading on the display.

Tip: For best efficiency, keep doors and windows closed in the room where the dehumidifier is operating.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean Air Filter: Remove and rinse filter under lukewarm water every 2-4 weeks. Let dry completely before reinstalling. Press FILTER RESET.
  2. Empty Water Tank: Regularly check and empty the tank before it becomes full to prevent automatic shut-off and overflow.
  3. Clean Exterior: Wipe the cabinet with a soft, damp cloth. Do not use harsh chemicals or abrasives.
  4. Clean Water Tank: Periodically wash the tank with mild soap and water to prevent mold/mildew. Rinse thoroughly.
  5. End-of-Season Storage: Empty and dry tank completely. Clean filter. Coil and secure the power cord. Store in a dry place.

WARNING! Always unplug the unit before performing any maintenance. Never immerse the main unit in water.

Drainage Options

Two methods for removing collected water: Manual (Bucket) and Continuous Drain.

Manual Drain: Use the built-in water tank. When the "Full Tank" light comes on, power off, pull out the tank, carry to a sink/drain, empty, and reinsert.

Continuous Drain:

  1. Locate the drain port (usually on the back).
  2. Remove the port cap/plug.
  3. Connect a standard garden hose (not included). Ensure hose is routed downhill without kinks.
  4. Place the other end of the hose into a floor drain, sink, or sump pump.
  5. The unit will now drain continuously; the water tank does not need to be emptied manually.

CAUTION! For continuous drain, the unit must be level and the hose outlet must be lower than the drain port.

Safety Information

Read all instructions before use.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This product meets applicable industry standards. Copyright and trademarks are property of Honeywell International Inc. or its affiliates. For support in the US and Canada, visit www.honeywellhome.com or contact 1-800-333-3993.

Troubleshooting

SymptomPossible CauseCorrective Action
Dehumidifier does not startNo power, full tank, set humidity metEnsure plugged in; outlet has power; empty tank; set humidity lower than current room level.
Little or no water collectionLow ambient temp, room already dry, filter cloggedOperate above 41°F; check if room RH is below set point; clean air filter.
Unit runs but air feels warmNormal operation in defrost modeDefrost cycle is automatic in cooler temps; unit will resume cooling.
Water leaking from unitTank not seated, hose connection loose, internal drain pan overflowEnsure tank is pushed in fully; check hose connection; stop unit and check for blockages.
Loud or unusual noiseUnit not level, fan hitting obstruction, compressor soundPlace on level surface; check for objects near fan; some compressor noise is normal.
"Filter" light is onAir filter needs cleaningClean the washable filter as per instructions and press the FILTER RESET button.

Reset: Unplug the unit for 5 minutes, then plug back in to reset the electronic controls.

Service: For issues not resolved above, contact Honeywell Customer Service at 1-800-333-3993 or visit the support website. Do not attempt to repair the unit yourself.