Honeywell TP-BIG Dehumidifier Manual

The Honeywell TP-BIG is a high-capacity dehumidifier designed for large spaces, featuring adjustable humidity control, continuous drainage option, auto-defrost, washable air filter, full tank alert with auto-shutoff, and energy-efficient operation. Suitable for basements, living areas, and other damp environments up to [Specify Area] square feet. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operation Modes 8. Maintenance & Cleaning 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: High-capacity compressor, adjustable humidistat, removable water tank with handle, continuous drainage port, washable filter, caster wheels for mobility, digital display, and control panel.

FeatureDescription
Adjustable HumidistatSet desired humidity level from 35% to 85%
Continuous DrainageOption to connect hose for automatic water removal
Auto-DefrostPrevents coil freezing in low temperatures
Full Tank Alert & Auto-ShutoffAlerts when tank is full and stops operation
Washable Air FilterCaptures dust and particles; reusable
Digital DisplayShows current humidity, settings, and alerts
24-Hour TimerProgram on/off cycles
Caster WheelsEasy mobility between rooms
Energy EfficientLow power consumption in standby mode
Turbo ModeMaximum moisture removal for rapid dehumidifying

Installation & Placement

Unpack and inspect contents. Place on a flat, stable surface away from obstructions.

  1. Choose Location: Place in center of room or area with high humidity, at least 6 inches from walls.
  2. Level Surface: Ensure unit is level for proper operation and water collection.
  3. Ventilation: Keep air intake and outlet grilles unobstructed.
  4. Power Connection: Plug directly into a grounded 120V AC outlet; avoid extension cords.

WARNING! Do not place near heat sources or in direct sunlight. Ensure the power cord is not pinched or damaged.

First-Time Setup

Power on the dehumidifier; configure initial settings.

  1. Insert Filter: Ensure washable filter is correctly installed behind front grille.
  2. Set Humidity: Press HUMIDITY button to set desired level (recommended 45-50%).
  3. Select Mode: Choose CONTINUOUS or AUTO mode based on needs.
  4. Check Drainage: Install water tank or connect drain hose if using continuous drainage.

CAUTION! Handle with care when moving; use two people if unit is heavy. Allow unit to upright for 24 hours if transported horizontally.

Specifications

Controls and Settings

Access controls via digital panel or remote control (if included). Front Panel: POWER, MODE, HUMIDITY, FAN SPEED, TIMER, TURBO, FILTER RESET.

Remote: POWER, MODE, HUMIDITY UP/DOWN, FAN, TIMER, TURBO.

Modes: CONTINUOUS (runs until turned off), AUTO (maintains set humidity). Fan Speed: LOW, MEDIUM, HIGH. Timer: Set 1-24 hours for automatic start/stop. Turbo: Maximum dehumidification speed. Filter Reset: Resets filter maintenance indicator after cleaning.

Connecting Drainage

For continuous operation, connect a drain hose (not included) to the drainage port.

  1. Turn off and unplug the unit.
  2. Remove water tank and locate drainage port at the back.
  3. Insert hose securely into port; ensure it runs downhill to floor drain or sink.
  4. Replace tank (unit will not operate without tank in place when hose is not used).

Tip: Use a standard garden hose (¾ inch). Ensure no kinks in the hose to allow free water flow.

Operation Modes

Supports multiple modes for efficient moisture removal.

  1. Auto Mode: Unit cycles on/off to maintain set humidity level.
  2. Continuous Mode: Runs constantly until turned off or tank is full.
  3. Turbo Mode: Runs fan at highest speed for fastest dehumidification.
  4. Timer: Program unit to start or stop after set hours.
  5. Sleep Mode: Reduces display brightness and operates quietly at night.

WARNING! Do not operate in temperatures below 41°F (5°C) unless Auto-Defrost is active. Empty tank regularly to prevent overflow.

Maintenance & Cleaning

Unplug before any maintenance. Clean every two weeks for optimal performance.

  1. Air Filter: Remove and wash with warm, soapy water; dry completely before reinstalling.
  2. Water Tank: Empty and clean with mild detergent; rinse thoroughly.
  3. Exterior: Wipe with a soft, damp cloth; do not use abrasive cleaners.
  4. Grilles and Coils: Use a vacuum brush attachment to remove dust.

CAUTION! Never immerse unit in water. Do not use chemicals on the filter. Allow all parts to dry completely before reassembly.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. ETL Listed for safety. Copyright © [Year] Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-333-6777.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueEnsure plugged in; check outlet; reset circuit breaker.
Not removing moistureSettings/filterCheck humidity setting; clean filter; ensure room temp above 41°F.
Water leakingTank/drain hoseEnsure tank is properly seated; check hose connection for leaks.
Loud noisePlacement/obstructionEnsure unit is level; check for objects touching fan or grille.
Display shows "Full" but tank is emptyFloat switch stuckGently shake unit to free float; check for debris in tank area.
Reduced airflowDirty filterClean or replace air filter.

Reset: Unplug for 1 minute, then restart. Press and hold POWER and MODE for 5 seconds to reset settings.

Service: 1-800-333-6777; www.honeywellhome.com