The Honeywell R-TP70 is a high-capacity 70-pint dehumidifier designed for residential use. It features automatic humidity control, continuous drainage capability, a washable air filter, a full tank alert with auto-shutoff, turbo mode for faster dehumidification, and a 24-hour timer. Ideal for basements, living areas, and other spaces up to 4,500 sq ft. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control Panel, Water Tank, Air Filter, Continuous Drain Hose Port, Casters, Handle.

FeatureDescription
Humidity ControlAdjustable from 35% to 85% relative humidity
Water TankRemovable 1.8-gallon capacity with full tank alert
Continuous DrainageGarden hose connection for automatic water removal
Washable FilterRemovable and reusable air filter
Turbo ModeHigh-speed dehumidification for maximum moisture removal
Auto RestartResumes previous settings after a power interruption
24-Hour TimerProgrammable on/off schedule
Auto DefrostPrevents frost buildup in low-temperature conditions
Digital DisplayShows current humidity, settings, and alerts
Power Cord StorageBuilt-in cord wrap for neat storage

Installation & Placement

Unpack and inspect contents. Place on a level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Environment: Ensure room temperature is between 41°F (5°C) and 95°F (35°C) for optimal operation.
  3. Power Connection: Plug directly into a grounded 120V AC outlet. Do not use an extension cord.
  4. Drainage Setup: Attach garden hose to drain port if using continuous drainage (optional).

WARNING! Do not place in tight corners or near heat sources. Ensure the unit is upright before operation.

First-Time Setup

Plug in the dehumidifier; the control panel will illuminate.

  1. Set Humidity Level: Press the HUMIDITY button to select desired level (35%-85%).
  2. Select Mode: Press MODE to choose between Normal, Turbo, or Timer operation.
  3. Check Filter: Ensure the air filter is clean and properly installed.
  4. Test Operation: Allow the unit to run for 15 minutes to confirm proper condensation and airflow.

CAUTION! Do not operate with an empty or improperly seated water tank. Handle the unit with care when moving.

Specifications

Controls and Settings

Access settings via the front control panel or included remote control.

Control Panel: POWER, HUMIDITY (+/-), MODE (Normal/Turbo/Timer), FILTER ALERT RESET, TIMER SET.

Remote: POWER, HUMIDITY, MODE, TIMER, FAN SPEED, SLEEP.

Humidity Control: Adjust target humidity in 5% increments. Timer: Set 1-24 hour delay for automatic start/stop. Filter Alert: LED illuminates when filter needs cleaning. Auto Shutoff: Activates when tank is full or removed. Turbo Mode: Increases fan speed for maximum moisture removal. Sleep Mode: Reduces display brightness and operates at low fan speed.

Operating Modes

Normal: Standard dehumidification with adjustable fan speed. Turbo: Maximum moisture removal for high humidity conditions. Timer: Programmable operation schedule. Continuous: Runs until tank is full or power is interrupted (when using drain hose).

  1. Press POWER to turn unit on.
  2. Use HUMIDITY buttons to set desired room humidity level.
  3. Press MODE to cycle through available operating modes.
  4. Monitor current humidity reading on digital display.

Tip: For energy savings, set humidity to 50-55% for most living spaces.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Water Tank: Empty regularly. Clean with mild detergent monthly.
  2. Air Filter: Remove and clean every 2 weeks under running water. Allow to dry completely before reinstalling.
  3. Exterior: Wipe with soft, damp cloth. Do not use abrasive cleaners.
  4. Coils: Vacuum condenser coils every 3 months to remove dust.
  5. Drain Hose: Check for clogs monthly if using continuous drainage.

WARNING! Always unplug unit before cleaning. Never immerse in water or use harsh chemicals.

Drainage Options

Two drainage methods: Manual (water tank) or Continuous (hose).

Manual: Unit stops when tank is full (Full Tank light illuminates). Remove tank, empty, and replace to resume operation.

Continuous: Attach standard garden hose (not included) to drain port. Ensure hose runs downward to floor drain or sink. Unit will operate continuously without interruption.

Care & Storage

When not in use for extended periods:

  1. Unplug unit and empty water tank completely.
  2. Clean filter and all accessible surfaces.
  3. Wrap power cord around storage hooks.
  4. Store upright in a cool, dry place.
  5. Cover with cloth or plastic to prevent dust accumulation.

CAUTION! Do not store with water in tank. Protect from extreme temperatures and direct sunlight.

Regulatory Information

UL Listed: Meets safety standards for household dehumidifiers. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device; complies with interference limits. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-333-3993. Refrigerant recovery and disposal must comply with local regulations.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueCheck outlet; ensure plug is secure; test outlet with another device.
Low dehumidificationDirty filter/cold roomClean air filter; ensure room temp is above 41°F; check for blocked airflow.
Water leakingTank not seated/hose leakEnsure tank is properly inserted; check hose connections for continuous drainage.
Loud noiseUneven surface/loose partsPlace on level floor; check for loose panels or foreign objects inside unit.
Full tank light on (empty tank)Float mechanism stuckRemove tank, check float moves freely; clean tank and float area.
Display shows error codeSensor/system errorUnplug for 10 minutes, then restart. If persists, contact service.

Reset: Unplug for 10 minutes to reset electronic controls.