The Honeywell R-TP50 is a high-capacity 50-pint dehumidifier designed for medium to large rooms, featuring automatic humidity control, a continuous drain option, a washable air filter, a full tank alert with auto-shutoff, a 24-hour timer, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Control Panel, Water Tank, Air Filter, Continuous Drain Hose Port, Casters for mobility, and Humidity Sensor.
| Feature | Description |
|---|---|
| Humidity Control | Automatic humidity sensing and adjustment with user-selectable target (30%-80% RH) |
| Water Tank | Removable 50-pint capacity tank with handle and full-tank indicator |
| Continuous Drain | Hose connection port for automatic water drainage |
| Air Filter | Washable mesh filter to capture dust and particles |
| Timer Function | 24-hour programmable on/off timer |
| Auto Shutoff | Automatically stops operation when tank is full |
| Turbo Mode | High-speed dehumidification for rapid moisture removal |
| Control Lock | Prevents accidental setting changes |
| Mobility | Four smooth-rolling casters for easy room-to-room movement |
| Energy Efficiency | Energy Star certified for lower power consumption |
Unpack and inspect contents. Place on a level, stable floor surface.
WARNING! Do not place on soft surfaces like carpet without a solid barrier. Ensure the unit is upright for at least 24 hours before first use if it was tilted during transport.
Plug into a dedicated 115V AC outlet; follow initial setup steps.
CAUTION! Use only a properly grounded outlet. Do not use an extension cord.
Access all functions via the digital control panel or included remote control.
Control Panel: POWER, MODE (Auto/Continuous/Turbo), HUMIDITY SET, FAN SPEED (Low/High), TIMER, FILTER ALERT RESET, CONTROL LOCK.
Remote: POWER, MODE, HUMIDITY UP/DOWN, TIMER, FAN SPEED.
Settings: Humidity Set Point (30%-80%), Fan Speed (Low for quiet operation, High for faster dehumidification), Mode (Auto - maintains set humidity, Continuous - runs constantly, Turbo - maximum moisture removal), Timer (program up to 24 hours).
Three primary modes for different needs.
Tip: For everyday use in a basement or living area, Auto mode at 50% RH is recommended.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always unplug the unit before any cleaning or maintenance. Never immerse the unit in water.
Two methods for water removal: manual via tank or continuous via hose.
Note: For hose drainage, the drain destination must be lower than the dehumidifier's drain port.
Built-in protections for safe operation.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. This product is Energy Star certified. For support in the US and Canada, contact Honeywell Customer Care at 1-800-332-1110 or visit www.honeywellhome.com. Copyright © Honeywell International Inc.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | No power, tank not inserted, control lock on | Check outlet; ensure tank is fully inserted; press and hold CONTROL LOCK for 3 seconds to unlock. |
| Little or no water collection | Low humidity, cold room temp, dirty filter, settings | Ensure room temp >41°F; clean filter; set humidity lower than current room level; use Turbo mode. |
| Unit runs but stops quickly | Full tank, 3-minute compressor delay | Empty tank; wait 3 minutes for normal compressor restart cycle. |
| Loud or unusual noise | Unit not level, loose parts, fan hitting obstruction | Place on level surface; check for loose panels; ensure filter is clean and properly installed. |
| Error Code "E1" displayed | Temperature sensor fault | Unplug for 60 seconds, then restart. If persists, contact service. |
| Water leaking from unit | Tank not seated, clogged drain hose, unit tilted | Remove and reinsert tank; check hose for kinks; ensure unit is level. |
Reset: Unplug unit for 5 minutes to reset control system.
Service: For repairs, contact authorized Honeywell service center. Do not attempt to disassemble the unit.