The Honeywell HDH-132 is a high-capacity dehumidifier designed for residential and light commercial use, capable of removing up to 50 pints of moisture per day (at 80°F, 60% RH). It features an auto-restart function, continuous drain option, adjustable humidistat, washable air filter, full tank alert with auto shut-off, caster wheels for mobility, and low-temperature operation capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Control panel with digital display, Water tank with handle, Casters for mobility, Air intake grille, Washable filter, Continuous drain hose port, Humidistat control.
| Feature | Description |
|---|---|
| Moisture Removal | Up to 50 pints per day (80°F/60% RH) |
| Water Tank Capacity | 1.6 gallons (with full tank alert) |
| Humidistat | Adjustable from 35% to 85% relative humidity |
| Auto Restart | Resumes previous settings after power interruption |
| Continuous Drain | Garden hose connection for unattended operation |
| Air Filter | Washable, removable filter for air quality |
| Low Temp Operation | Functions down to 41°F (5°C) |
| Digital Controls | LED display for humidity level and alerts |
| Turbo Mode | High-speed moisture removal |
| Caster Wheels | Four wheels for easy room-to-room mobility |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place in closets or confined spaces. Ensure proper ventilation for optimal performance.
Power on dehumidifier; follow initial setup steps.
CAUTION! Handle with care when moving; use two people if necessary. Unit contains refrigerant.
Control Panel: POWER button, MODE selector, HUMIDITY UP/DOWN, TURBO button, FILTER indicator, FULL TANK indicator.
Display: Current room humidity, Set humidity, Mode indicators, Alert icons.
Modes: CONTINUOUS (runs until turned off), AUTO (cycles based on humidistat setting), TURBO (maximum moisture removal). Settings: Humidity level adjustment, 24-hour timer, Filter reset, Drain mode selection. Alerts: Full tank, Filter clean, Defrost cycle, Error codes.
Three operating modes for different needs.
Tip: Start with AUTO mode at 50% humidity. Adjust based on comfort and conditions.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug before cleaning. Do not immerse in water. Handle filter carefully.
Two methods for water removal: manual tank or continuous drain.
CAUTION! Do not lift unit with full water tank. Empty before moving.
Auto Shut-off: When tank is full. Overload Protection: Thermal fuse protects compressor. Tip-over Switch: Stops operation if unit tips. Child Lock: Prevents accidental setting changes. Anti-frost Sensor: Prevents coil freezing in low temps.
UL Listed: Meets UL 474 safety standards. Energy Star: Compliant with EPA energy efficiency requirements. FCC Part 15: Class B digital device. Refrigerant: Contains R410A, comply with EPA Section 608 regulations. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power issue/full tank | Check outlet; reset GFCI; ensure tank is empty and properly seated. |
| Little/no water collection | Low humidity/cold temps | Check room humidity; ensure temp above 41°F; clean filter. |
| Loud noise/vibration | Uneven surface/obstruction | Level unit; check for objects near fan; tighten components. |
| Error code E1/E2 | Sensor failure | Unplug for 10 minutes; restart. If persists, contact service. |
| Water leakage | Tank not seated/hose leak | Ensure tank properly installed; check hose connections; clean drain port. |
| Ice on coils | Low temperature | Unit will auto-defrost; raise room temp above 50°F if possible. |
| Musty odor | Dirty filter/stagnant water | Clean filter; empty and clean tank; run unit in ventilated area. |
Reset: Unplug for 10 minutes to reset electronic controls.
Service: 1-800-332-1110; www.honeywellhome.com