Honeywell HD016E Dehumidifier Manual

The Honeywell HD016E is a portable dehumidifier designed to remove excess moisture from the air in rooms up to 3000 cubic feet. It features a 16-pint per day removal capacity (at 80°F, 60% RH), an auto-restart function, a continuous drain option, a full-tank alert with auto-shutoff, a washable filter, adjustable humidity control, and a quiet operation mode. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Operation 6. Drainage Options 7. Maintenance & Cleaning 8. Energy Saving Tips 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Main unit with control panel, Water collection tank, Washable air filter, Power cord, Drain hose adapter, User manual.

FeatureDescription
CapacityRemoves up to 16 pints per day (at 80°F, 60% RH)
HumidistatAdjustable digital humidity control (30% - 80% RH)
Water Tank1.8-gallon (6.8 L) removable bucket with handle
Full Tank AlertIndicator light and auto-shutoff when tank is full
Continuous DrainOption for hose connection (hose not included)
Auto RestartResumes previous settings after a power interruption
Air FilterWashable mesh filter to capture dust and particles
Quiet OperationLow-noise design for bedrooms and living areas
Control PanelDigital display with touch buttons
Timer Function24-hour programmable on/off timer

Installation & Placement

Unpack and inspect contents. Choose a suitable location.

  1. Place on a level, stable surface: Ensure unit is upright and not tilted.
  2. Clearance: Allow at least 12 inches of space around air vents (front, back, and sides).
  3. Ambient temperature: Operate between 41°F (5°C) and 95°F (35°C) for optimal performance.
  4. Power connection: Plug directly into a grounded 120V AC, 60Hz outlet. Do not use an extension cord.

WARNING! Do not place near heat sources or in direct sunlight. Ensure the room is adequately sealed for efficient dehumidification.

First-Time Setup

Power on the dehumidifier; configure initial settings.

  1. Insert the water tank: Push firmly into place until it clicks.
  2. Power on: Plug in and press the POWER button. The unit will beep and the display will light up.
  3. Set desired humidity: Use the UP/DOWN buttons to set your target relative humidity (e.g., 45%-55%).
  4. Select fan speed: Choose between HIGH (faster dehumidification) or LOW (quieter operation).
  5. Optional timer: Press TIMER to program automatic start/stop times.

CAUTION! Handle the water tank with care to avoid spills. Ensure the filter is clean and properly installed before first use.

Specifications

Controls and Operation

Access all functions via the digital control panel on the top of the unit.

Control Panel Buttons & Display: POWER, MODE (Continuous/Target Humidity), FAN SPEED (High/Low), TIMER (2/4/8/12 Hr or 24Hr Program), UP/DOWN (Humidity Setpoint), FILTER ALERT (Reset). Display shows: Set Humidity, Current Humidity, Fan Speed Icon, Timer Icon, Full Tank Alert, Filter Alert.

Basic Operation: Press POWER. Use MODE to choose between CONTINUOUS (runs constantly) or TARGET (stops at set humidity). Use UP/DOWN to adjust target humidity. Use FAN SPEED to select airflow. The compressor will cycle on and off automatically to maintain the set humidity level.

Drainage Options

Two methods for removing collected water: Manual (bucket) or Continuous (hose).

  1. Manual Drainage (Bucket):
    • When the tank is full, the unit will beep, the "FULL" indicator will light, and it will shut off.
    • Grip the tank handle, pull straight out, and carry to a sink or drain.
    • Empty water, replace tank firmly. The unit will resume operation if power is on.
  2. Continuous Drainage (Hose):
    • Remove the water tank. Locate the drain outlet on the back of the unit.
    • Connect a standard 5/8" inner diameter garden hose (not included) to the outlet.
    • Route the hose to a floor drain or sink. Ensure the hose path is downhill without kinks.
    • Replace the empty water tank. The unit will now drain continuously, ignoring the tank.

Tip: For basement use, continuous drainage is recommended. Ensure the drain point is lower than the dehumidifier outlet.

Maintenance & Cleaning

Unplug the unit before any maintenance.

  1. Cleaning the Air Filter:
    • Remove the filter grill (usually on the back). Pull out the washable filter.
    • Vacuum loose dust or rinse under lukewarm water. Let air dry completely.
    • Reinstall the filter and grill. Press the FILTER button for 3 seconds to reset the alert.
    • Frequency: Clean every 2 weeks under normal use; more often in dusty environments.
  2. Cleaning the Water Tank:
    • To prevent mold/mildew, clean the tank monthly with a mild detergent and soft cloth.
    • Rinse thoroughly. Do not use abrasive cleaners.
  3. Exterior Cleaning:
    • Wipe the cabinet with a soft, damp cloth. Do not use chemicals or allow water inside vents.
  4. End-of-Season Storage:
    • Empty and clean the tank. Let the unit run in FAN ONLY mode for a few hours to dry the coils.
    • Unplug, coil the power cord, and store in a dry, cool place. Cover to prevent dust.

CAUTION! Never immerse the unit in water. Do not operate without the filter installed.

Energy Saving Tips

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Honeywell International Inc. Honeywell and the Honeywell logo are trademarks of Honeywell International Inc. For support, visit www.honeywellpluggedin.com or contact customer service at 1-800-474-2147.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power, full tank, timer setEnsure plug is secure. Empty water tank. Check timer settings.
Little or no water collectionLow room temp, low humidity, dirty filterUse in recommended temp range (41°F+). Check room RH. Clean air filter.
Unit runs but air feels warmNormal operationThe exhaust air is slightly warmer than inlet air. This is normal.
Loud or unusual noiseUneven placement, loose partsPlace on a level floor. Ensure water tank and filter are securely installed.
"FULL" light is on but tank is not fullFloat mechanism stuckRemove tank, check for obstruction around the float. Reinstall tank firmly.
Error Code "E1" or "E2" on displaySensor faultUnplug for 5 minutes, then restart. If persists, contact service.

Reset: Unplug the unit for 5 minutes to perform a full system reset.

Service: For repairs, do not attempt to disassemble the unit. Contact authorized service: 1-800-474-2147 or www.honeywellpluggedin.com.