The Honeywell DH90A1007 is a whole-house dehumidifier designed for residential use, capable of removing up to 90 pints of moisture per day. It features automatic humidity control, a built-in condensate pump, digital controls with a display, washable air filter, continuous drain option, and compatibility with standard ductwork. Ideal for basements, crawl spaces, and large living areas to improve indoor air quality and comfort. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital control panel, built-in condensate pump, washable air filter, duct collars (supply and return), humidity sensor, continuous drain port, and front grille for easy access.
| Feature | Description |
|---|---|
| Digital Control Panel | LCD display for humidity setting, fan speed, and system status |
| Built-in Condensate Pump | Pumps water vertically up to 15 feet for flexible drainage |
| Washable Air Filter | Captures dust and particles; reusable after cleaning |
| Duct Collars | Standard 8-inch ducts for integration into HVAC system |
| Humidity Sensor | Automatically monitors and adjusts to set humidity level |
| Continuous Drain Port | For gravity drain option using 5/8" ID hose |
| Front Grille | Removable for easy filter access and maintenance |
| Auto Restart | Resumes previous settings after power outage |
| Fan Speed Control | Adjustable between low and high settings |
| Filter Alert Indicator | LED light reminds when filter needs cleaning |
Unpack and inspect contents. Ensure installation location is level, with adequate clearance for airflow and service access.
WARNING! Unit is heavy; use two people for lifting. Ensure all duct connections are airtight to prevent moisture loss.
Power on dehumidifier; follow initial setup steps on digital display.
CAUTION! Allow unit to sit upright for 24 hours if transported horizontally before powering on.
Access settings via digital control panel on front of unit.
Control Panel: POWER button, UP/DOWN buttons, FAN SPEED button, FILTER RESET button, LCD display.
Humidity Setting: Adjust between 35% and 80% RH. Fan Speed: Toggle between LOW and HIGH. Filter Alert: LED illuminates when filter needs cleaning; press FILTER RESET after cleaning. Pump Status: Display shows "Pump" when active. Continuous Operation: Hold DOWN button for 3 seconds to enable/disable continuous run mode.
Two drainage options: condensate pump or continuous gravity drain.
Tip: Use insulated tubing in cold spaces to prevent condensation freeze-up.
Supports automatic humidity control, continuous operation, and fan-only mode.
WARNING! Do not operate below 55°F ambient temperature without low-temperature kit (sold separately).
Regular maintenance ensures optimal performance and longevity.
Unplug unit before cleaning. Use damp cloth for exterior; vacuum filter with soft brush attachment.
CAUTION! Do not use harsh chemicals, steam, or high-pressure water on coils or electrical components.
UL Listed. Meets EPA refrigerant standards. FCC Part 15 Class B compliant. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-468-1502. This product contains R-410A refrigerant; proper disposal required by certified technician.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not powering on | Power source/breaker | Check outlet; reset circuit breaker; ensure plug is fully inserted. |
| Not removing moisture | Filter/ducts/temperature | Clean filter; check for blocked ducts; ensure room temp above 55°F. |
| Water not draining | Pump/clogged line | Check pump operation; clear drain line of obstructions; ensure proper slope. |
| Loud noise | Loose parts/fan | Tighten access panels; check for debris in fan wheel; ensure unit is level. |
| Display shows "Error" | Sensor/component fault | Power cycle unit; check sensor connections; call service if persistent. |
Reset: Unplug for 60 seconds, then restart.
Service: 1-800-468-1502; www.honeywellhome.com