The Honeywell DH70PWGN is a 70-pint portable dehumidifier designed for residential use in spaces up to 4500 sq. ft. It features a built-in pump for continuous drainage, digital humidistat with auto-defrost, washable air filter, 24-hour timer, auto-restart, and energy-saving modes. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Digital control panel, Built-in condensate pump, Washable air filter, 2.1-gallon water tank, Continuous drainage port, Casters for mobility.
| Feature | Description |
|---|---|
| Built-in Pump | Enables vertical drainage up to 16 feet |
| Digital Humidistat | Precise humidity control from 35% to 85% RH |
| Auto-Defrost | Prevents coil freezing in low temperatures |
| Washable Air Filter | Captures dust and particles; reusable |
| 24-Hour Timer | Program on/off cycles |
| Auto-Restart | Resumes previous settings after power outage |
| Energy Saver Mode | Fan stops when target humidity is reached |
| Full Tank Alert | LED indicator and auto-shutoff when tank is full |
| Continuous Drainage | Garden hose connection for permanent drainage |
| Portable Design | Four casters for easy room-to-room movement |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not operate in temperatures below 41°F (5°C). Ensure unit is upright for 24 hours before first use if transported sideways.
Power on unit; follow control panel prompts.
CAUTION! Empty water tank before moving unit. Do not block air intake or exhaust.
Control Panel: POWER, MODE, HUMIDITY, TIMER, PUMP, FILTER RESET.
Display Indicators: Current humidity, Set humidity, Timer, Full tank, Filter alert, Pump status.
Modes: CONTINUOUS (runs constantly), AUTO (maintains set humidity), ENERGY SAVER (fan stops when target reached). Timer: Programmable in 1-hour increments up to 24 hours. Humidity Control: Adjust in 5% increments. Pump: ON/OFF switch for vertical drainage. Filter Reset: Press after cleaning filter.
Two drainage methods: Water tank or continuous drainage.
Tip: For basement use, pump drainage is recommended. Ensure hose is not kinked.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug unit before cleaning. Never immerse in water.
Use ENERGY SAVER mode to reduce power consumption. Set humidity to 50% or higher for less frequent operation. Close windows and doors in room being dehumidified. Use timer to run during peak humidity hours only.
FCC Part 15: Class B digital device; complies with interference limits for residential use. ETL listed. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power issue/full tank | Check power outlet; empty water tank; ensure filter is clean. |
| Low moisture removal | Room temperature/low humidity | Ensure room temp is above 41°F; check humidity setting. |
| Pump not working | Clog/kink in hose | Check hose for obstructions; ensure pump switch is ON. |
| Loud noise | Loose parts/foreign objects | Ensure unit is level; check for objects near fan. |
| Error code E1/E2 | Sensor failure/temperature issue | Unplug for 10 minutes; restart. If persists, contact service. |
| Water leakage | Improper hose connection | Check all connections; ensure tank is properly seated. |
Reset: Unplug for 10 minutes to reset control board.
Service: 1-800-332-1110; www.honeywellhome.com