Honeywell DH70PW Dehumidifier Manual

The Honeywell DH70PW is a high-capacity 70-pint dehumidifier designed for large rooms and basements, featuring automatic humidity control, continuous drainage option, washable filter, digital controls with LED display, auto-restart after power interruption, turbo mode for faster dehumidification, and a 24-hour timer. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, 70-pint water tank, Continuous drain hose port, Washable air filter, Casters for mobility, Handle for transport.

FeatureDescription
Digital Control PanelLED display with humidity readout and control buttons
70-Pint Water TankRemovable bucket with full-tank indicator and auto-shutoff
Continuous Drain PortFor hose connection to drain water automatically
Washable Air FilterCaptures dust and particles; can be cleaned
Casters & HandleFor easy mobility around the room
Turbo ModeIncreases fan speed for faster dehumidification
24-Hour TimerProgram on/off times for energy savings
Auto Humidity ControlMaintains set humidity level automatically
Auto-RestartResumes previous settings after power outage
Filter Alert IndicatorLED light reminds when to clean the filter

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room away from walls/furniture for optimal airflow.
  2. Check clearance: Ensure at least 12 inches of space on all sides.
  3. Level surface: Use on hard floor; avoid carpets that block bottom air intake.
  4. Set up drainage: Attach hose to drain port if using continuous drainage.
  5. Plug into grounded 120V AC outlet.

WARNING! Do not place near heat sources or in direct sunlight. Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; follow initial setup steps.

  1. Install water tank: Insert bucket fully until it clicks into place.
  2. Set humidity level: Press HUMIDITY button to select desired level (35%-85%).
  3. Select mode: Choose between Normal, Turbo, or Timer mode.
  4. Check filter: Ensure filter is clean and properly installed.
  5. Test operation: Run for 15 minutes to verify proper dehumidification.

CAUTION! Handle water tank carefully when full; empty before moving unit.

Specifications

Controls and Settings

Control Panel: POWER button, HUMIDITY +/- buttons, MODE button, TIMER button, FILTER RESET button.

LED Display: Current humidity, Set humidity, Timer settings, Filter alert, Full tank indicator.

Humidity Setting: Adjust between 35%-85% in 5% increments. Mode Selection: Normal (standard operation), Turbo (high-speed dehumidification), Timer (programmed operation). Timer Function: Set 1-24 hours for automatic on/off. Filter Reset: Press after cleaning filter to reset alert light.

Operation Modes

Normal Mode: Standard dehumidification with balanced fan speed. Turbo Mode: Maximum dehumidification for very damp conditions. Timer Mode: Program unit to run at specific times.

  1. Press POWER to turn unit on.
  2. Press MODE to cycle through Normal, Turbo, Timer.
  3. In Timer mode, use +/- buttons to set hours (1-24).
  4. Unit will maintain set humidity automatically.
  5. Full tank indicator lights when bucket needs emptying.

Tip: Use Turbo mode initially in very damp rooms, then switch to Normal.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter every 2 weeks: Remove, wash with warm water, dry completely.
  2. Empty water tank regularly: When full indicator lights or tank is full.
  3. Clean exterior: Wipe with damp cloth; do not use chemicals or abrasives.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Off-season storage: Empty tank, clean unit, store in dry place.

WARNING! Always unplug unit before cleaning. Never immerse in water.

Drainage Options

Bucket Drainage: Manual emptying of 1.8-gallon tank. Continuous Drainage: Connect hose to drain port for automatic water removal.

  1. For bucket: Remove when full, empty, replace securely.
  2. For continuous: Attach 5/8" ID hose to drain port, route to floor drain.
  3. Ensure hose has downward slope without kinks.
  4. Unit will drain automatically when hose connected.

CAUTION! Do not lift unit when hose is attached. Ensure proper drainage slope.

Safety Features

Auto Shutoff: Stops operation when tank is full. Tip-Over Protection: Turns off if unit is knocked over. Overheat Protection: Shuts down compressor if overheated. Child Lock: Locks control panel to prevent accidental changes.

Regulatory Information

UL Listed: Meets safety standards for household use. Energy Star Certified: Meets energy efficiency guidelines. EPA Refrigerant Compliance: Uses R410a refrigerant. Copyright © Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-332-1110.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueCheck power cord connection; ensure outlet works; check circuit breaker.
Not removing moistureSettings/temperatureCheck humidity setting; ensure room temperature above 41°F; clean filter.
Water leakingTank/drain issuesEnsure tank properly seated; check drain hose connection; clear blockages.
Loud noiseObstructions/placementCheck for objects near fan; ensure unit is level; clean filter.
Filter light onDirty filterClean filter thoroughly; press FILTER RESET button.
Ice on coilsLow temperatureTurn unit off; let ice melt; use in warmer conditions (above 41°F).

Reset: Unplug for 5 minutes, then restart if issues persist.

Service: 1-800-332-1110; www.honeywellhome.com

Honeywell DH70PW Dehumidifier Manual © - All Rights Reserved 2025