Honeywell DH45WGN Dehumidifier Manual

The Honeywell DH45WGN is a 45-pint capacity dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drain option, washable filter, auto defrost, digital humidistat, full tank alert with auto shut-off, caster wheels for mobility, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drain Hose 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Digital control panel, 45-pint water tank, washable air filter, continuous drain port, caster wheels, humidistat, full tank indicator.

FeatureDescription
Capacity45 pints per day (at 60°F, 60% RH)
Digital HumidistatSet desired humidity level (35% - 85%)
Auto DefrostPrevents coil freezing in low temperatures
Continuous DrainOption for hose connection (hose not included)
Washable FilterRemovable filter for easy cleaning
Full Tank AlertIndicator light and auto shut-off when tank is full
Caster WheelsFour wheels for easy mobility
Control PanelDigital display with touch buttons
Power Cord6-foot cord with storage wrap
Operating Range41°F to 95°F

Installation

Unpack and inspect contents. Place on level surface.

  1. Remove packaging materials and tape from unit.
  2. Position dehumidifier: Place on level floor at least 12 inches from walls and furniture.
  3. Install casters: Attach all four wheels to base (if not pre-installed).
  4. Check filter: Ensure washable filter is properly seated.
  5. Plug into grounded 120V AC outlet.

WARNING! Do not use extension cords. Ensure proper ventilation around unit.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Set humidity level: Press HUMIDITY button to set desired level (45-50% recommended).
  2. Select mode: Choose between CONTINUOUS or AUTO mode.
  3. Check drain options: Decide between bucket collection or continuous drain.
  4. Test operation: Run for 24 hours to establish baseline performance.
  5. Adjust placement: Move unit if needed for optimal moisture removal.

CAUTION! Do not operate in temperatures below 41°F without auto defrost feature enabled.

Specifications

Controls and Settings

Digital control panel features: POWER, MODE, HUMIDITY, FAN SPEED, TIMER.

Display Indicators: Current humidity, set point, filter alert, full tank, defrost mode.

Humidity Control: Set between 35% and 85% in 5% increments. Modes: CONTINUOUS (runs constantly), AUTO (cycles based on humidity setting). Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: 1-24 hours for automatic shut-off. Filter Alert: Light indicates when filter needs cleaning.

Connecting Drain Hose

For continuous operation without emptying bucket.

  1. Turn off and unplug unit.
  2. Remove drain plug from back of unit.
  3. Attach 5/8" ID hose (not included) to drain port.
  4. Route hose to floor drain or suitable drainage area.
  5. Ensure hose has downward slope without kinks.
  6. Replace bucket to catch any potential overflow.

Tip: Use hose clamp to secure connection and prevent leaks.

Operating Modes

Three main operating modes for different needs.

  1. AUTO Mode: Unit cycles on/off to maintain set humidity level.
  2. CONTINUOUS Mode: Runs constantly until turned off or tank is full.
  3. LAUNDRY Mode: High-speed drying for laundry rooms (runs 4 hours then switches to AUTO).
  4. Fan Only: Circulates air without dehumidifying.
  5. Turbo: Maximum moisture removal for high humidity conditions.

WARNING! Do not operate in standing water. Keep unit upright during operation.

Maintenance

Regular maintenance ensures optimal performance and longevity.

TaskFrequencyProcedure
Empty Water TankAs neededRemove, empty, and replace securely
Clean FilterEvery 2 weeksWash with warm water, dry completely
Clean ExteriorMonthlyWipe with damp cloth, then dry
Check Drain HoseMonthlyEnsure clear of obstructions
Coil InspectionSeasonallyCheck for dust/debris, vacuum if needed

Care & Cleaning

Unplug before cleaning. Use mild detergent and soft cloth.

  1. Exterior: Wipe with damp cloth. Do not use abrasive cleaners.
  2. Water Tank: Clean with mild soap solution, rinse thoroughly.
  3. Filter: Remove, wash under running water, air dry completely before reinstalling.
  4. Grille and Vents: Use soft brush attachment on vacuum cleaner.
  5. Storage: Empty tank, clean unit, wrap cord, cover with plastic bag.

CAUTION! Never immerse unit in water. Do not use chemical cleaners on coils.

Regulatory Information

UL Listed. EPA Energy Star certified. Meets California Air Resources Board (CARB) requirements. Manufactured for Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147. This product contains refrigerant that must be recovered by certified technicians.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/full tankCheck power outlet; empty water tank; reset circuit breaker.
Poor dehumidificationDirty filter/room too coldClean filter; ensure room temperature above 41°F.
Water leakageImproper hose connectionCheck drain hose connection; ensure tank properly seated.
Loud noiseLoose parts/obstructionCheck for loose panels; remove obstruction from fan.
Frost on coilsLow temperatureAuto defrost should activate; move to warmer area.
Error codesSensor issuesUnplug for 10 minutes, then restart; contact support if persistent.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-474-2147; www.honeywellhome.com

Honeywell DH45WGN Dehumidifier Manual © - All Rights Reserved 2025