The Honeywell DH45WGN is a 45-pint capacity dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drain option, washable filter, auto defrost, digital humidistat, full tank alert with auto shut-off, caster wheels for mobility, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Digital control panel, 45-pint water tank, washable air filter, continuous drain port, caster wheels, humidistat, full tank indicator.
| Feature | Description |
|---|---|
| Capacity | 45 pints per day (at 60°F, 60% RH) |
| Digital Humidistat | Set desired humidity level (35% - 85%) |
| Auto Defrost | Prevents coil freezing in low temperatures |
| Continuous Drain | Option for hose connection (hose not included) |
| Washable Filter | Removable filter for easy cleaning |
| Full Tank Alert | Indicator light and auto shut-off when tank is full |
| Caster Wheels | Four wheels for easy mobility |
| Control Panel | Digital display with touch buttons |
| Power Cord | 6-foot cord with storage wrap |
| Operating Range | 41°F to 95°F |
Unpack and inspect contents. Place on level surface.
WARNING! Do not use extension cords. Ensure proper ventilation around unit.
Power on dehumidifier; configure initial settings.
CAUTION! Do not operate in temperatures below 41°F without auto defrost feature enabled.
Digital control panel features: POWER, MODE, HUMIDITY, FAN SPEED, TIMER.
Display Indicators: Current humidity, set point, filter alert, full tank, defrost mode.
Humidity Control: Set between 35% and 85% in 5% increments. Modes: CONTINUOUS (runs constantly), AUTO (cycles based on humidity setting). Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: 1-24 hours for automatic shut-off. Filter Alert: Light indicates when filter needs cleaning.
For continuous operation without emptying bucket.
Tip: Use hose clamp to secure connection and prevent leaks.
Three main operating modes for different needs.
WARNING! Do not operate in standing water. Keep unit upright during operation.
Regular maintenance ensures optimal performance and longevity.
| Task | Frequency | Procedure |
|---|---|---|
| Empty Water Tank | As needed | Remove, empty, and replace securely |
| Clean Filter | Every 2 weeks | Wash with warm water, dry completely |
| Clean Exterior | Monthly | Wipe with damp cloth, then dry |
| Check Drain Hose | Monthly | Ensure clear of obstructions |
| Coil Inspection | Seasonally | Check for dust/debris, vacuum if needed |
Unplug before cleaning. Use mild detergent and soft cloth.
CAUTION! Never immerse unit in water. Do not use chemical cleaners on coils.
UL Listed. EPA Energy Star certified. Meets California Air Resources Board (CARB) requirements. Manufactured for Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-474-2147. This product contains refrigerant that must be recovered by certified technicians.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not running | Power issue/full tank | Check power outlet; empty water tank; reset circuit breaker. |
| Poor dehumidification | Dirty filter/room too cold | Clean filter; ensure room temperature above 41°F. |
| Water leakage | Improper hose connection | Check drain hose connection; ensure tank properly seated. |
| Loud noise | Loose parts/obstruction | Check for loose panels; remove obstruction from fan. |
| Frost on coils | Low temperature | Auto defrost should activate; move to warmer area. |
| Error codes | Sensor issues | Unplug for 10 minutes, then restart; contact support if persistent. |
Reset: Unplug for 10 minutes to reset electronic controls.
Service: 1-800-474-2147; www.honeywellhome.com