The Honeywell 848987003139 is a portable dehumidifier designed to remove excess moisture from the air in rooms up to a specified size. It features adjustable humidity control, continuous drainage option, auto-defrost, water tank full alert, and quiet operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Dehumidifier unit, Removable water tank, Control panel, Air filter, Power cord, Drain hose adapter.
| Feature | Description |
|---|---|
| Humidity Control | Adjustable digital humidistat with LED display |
| Water Tank | Removable tank with full indicator and auto-shutoff |
| Continuous Drainage | Option to connect a hose for continuous water removal |
| Auto-Defrost | Automatically defrosts coils in low temperatures |
| Quiet Operation | Low-noise design for bedrooms and living areas |
| Timer Function | Programmable on/off timer |
| Air Filter | Washable filter to capture dust and particles |
| Carry Handle | Integrated handle for easy portability |
| Power Cord Storage | Compartment to wrap and store excess cord |
| Control Lock | Prevents accidental setting changes |
Unpack and inspect contents. Place on a flat, stable surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure unit is upright before operation.
Plug into a grounded 120V AC outlet; follow initial setup steps.
CAUTION! Handle water tank with care to avoid spills. Do not operate without filter installed.
Access functions via front control panel or remote (if included).
Control Panel: POWER, MODE, TIMER, UP/DOWN (humidity/fan), FILTER RESET, LOCK.
Humidity Setting: Use UP/DOWN to set target humidity (40-80%). Modes: CONTINUOUS (runs until tank full), AUTO (maintains set humidity), TIMER (program on/off). Fan Speed: Adjust between HIGH and LOW. Filter Alert: FILTER RESET light indicates when to clean filter. Control Lock: Press and hold LOCK for 3 seconds to disable buttons.
Auto Mode: Unit cycles on/off to maintain set humidity level. Continuous Mode: Runs constantly until tank is full or unit is turned off. Timer Mode: Set to run for 2, 4, 8, or 12 hours then shut off.
Tip: Use AUTO mode for energy efficiency. Ensure drain hose is securely attached and not kinked.
Unplug unit before any maintenance.
WARNING! Do not immerse unit in water. Never operate without the air filter.
If not using for more than 2 weeks, prepare for storage.
CAUTION! Store upright. Do not place heavy objects on top.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © [Year] Honeywell International Inc.; Honeywell is a trademark of Honeywell International Inc. For support, visit www.honeywellhome.com or contact 1-800-333-7467.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | No power / Full tank | Ensure plug is secure; empty water tank; check circuit breaker. |
| Low dehumidification | Room too cold / Dirty filter | Operate above 41°F (5°C); clean or replace air filter. |
| Water leaking | Tank not seated / Hose leak | Remove and reinsert tank; check hose connections for continuous drain. |
| Loud noise | Uneven surface / Loose parts | Place on level floor; ensure internal components are secure. |
| FULL light on but tank not full | Float stuck | Remove tank, check float mechanism moves freely, clean if necessary. |
| Frost on coils | Low room temperature | Auto-defrost should activate; move unit to warmer area if persistent. |
Reset: Unplug for 60 seconds, then restart. Press FILTER RESET after cleaning filter.
Service: 1-800-333-7467; www.honeywellhome.com