The Honeywell 848987003122 is a portable dehumidifier designed to remove excess moisture from the air in rooms up to a specified size. It features adjustable humidity control, continuous drainage capability, an auto-defrost function, a full tank alert with auto-shutoff, washable air filter, and caster wheels for easy mobility. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Dehumidifier unit with water tank, Control Panel, Air Filter, Casters, Drain Hose Outlet, and Power Cord.
| Feature | Description |
|---|---|
| Humidity Control | Adjustable digital or dial control to set desired room humidity level |
| Water Tank | Removable bucket with handle and full-tank indicator/auto-shutoff |
| Continuous Drainage | Outlet for connecting a hose (not included) for automatic water removal |
| Auto Defrost | Automatically defrosts coils in low-temperature conditions |
| Washable Air Filter | Captures airborne particles; can be cleaned and reused |
| Caster Wheels | Four wheels for easy portability |
| Control Panel | Power button, humidity setting, fan speed, timer functions |
| Full Tank Alert | Indicator light and audible alert when tank is full |
| Power Cord Storage | Compartment or hooks for neat cord storage |
Unpack and inspect contents. Place on a flat, stable, and level surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure the unit is upright before operating.
Before first use, prepare the dehumidifier.
CAUTION! Allow the unit to stand upright for at least 30 minutes after moving before turning it on, especially if it was tilted.
Access functions via the control panel on the top of the unit.
Control Panel Buttons/Display: POWER, HUMIDITY SET (+/-), FAN SPEED (High/Low), TIMER (On/Off), FILTER ALERT Reset.
Humidity Setting: Press HUMIDITY buttons to set your desired room humidity level (e.g., 45%, 50%, 55%). The unit will cycle on and off to maintain this level.
Fan Speed: Select HIGH for maximum moisture removal or LOW for quieter operation.
Timer: Set the unit to automatically turn ON or OFF after a set number of hours.
Continuous Mode: Some models allow you to override the humidity setting for constant operation until the tank is full.
For normal daily use to control humidity.
Tip: For initial drying of a very damp room, set the humidity level to the lowest setting (or Continuous mode) and use HIGH fan speed.
Regular maintenance ensures optimal performance and longevity.
CAUTION! Always unplug the unit before performing any maintenance. Never immerse the unit in water.
For unattended operation, connect a garden hose (not included) for continuous water drainage.
Note: For proper drainage, the hose must run downward without loops or sags that could trap water.
This dehumidifier complies with relevant U.S. safety and performance standards. It uses refrigerant R410a. For electrical safety, it is ETL listed or certified. Copyright and trademarks are property of Honeywell International Inc. For support, visit www.honeywellhome.com or contact Honeywell Customer Care at 1-800-474-2147.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit does not start | No power, full tank, timer set | Ensure unit is plugged in; outlet has power; empty water tank; check timer settings. |
| Little or no water collection | Room humidity already low, cold room, dirty filter | Check room humidity with a hygrometer; ensure room temp is above 41°F; clean the air filter. |
| Unit runs but stops quickly | Desired humidity level reached, auto-defrost cycle | This is normal cycling. If in a cold room, the auto-defrost may cycle the compressor off periodically. |
| Water leaking from unit | Tank not seated, hose connection loose, internal drain pan clogged | Remove and reinsert tank firmly; check hose connection; unplug unit and inspect/clean internal drain area. |
| Loud or unusual noise | Unit not level, fan hitting obstruction, loose part | Place unit on level floor; check for and remove any obstruction near fan; ensure cabinet panels are secure. |
| "Filter" light is on | Air filter needs cleaning | Clean the washable air filter as per instructions. Press and hold FILTER RESET button for 3 seconds. |
Reset: Unplug the unit for 5 minutes, then plug it back in to reset the electronic controls.
Service: For persistent issues, contact Honeywell Customer Care at 1-800-474-2147 or visit www.honeywellhome.com. Do not attempt to repair the sealed refrigeration system yourself.